GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provide an overview of each diagnostic category.

Circuit/System Description

Ignition voltage is supplied to the malfunction indicator lamp (MIL). The powertrain control module (PCM) turns the MIL ON by grounding the MIL control circuit.

Reference Information

Schematic Reference

    •  Instrument Cluster Schematics
    •  Engine Controls Schematics

Connector End View Reference

    •  Displays and Gages Connector End Views
    •  Powertrain Control Module Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

    •  Scan Tool Data List
    •  Scan Tool Data Definitions
    •  Scan Tool Output Controls

Circuit/System Verification

Ignition ON, the MIL should turn ON and OFF when commanded with a scan tool.

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the instrument panel cluster (IPC).
  2. Ignition ON, verify that a test lamp illuminates between the ignition circuit and ground.
  3. If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, test all components connected to the fuse and replace as necessary.
  4. Connect a test lamp between the control circuit and the ignition circuit.
  5. Command the MIL ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.
  6. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the PCM.
    If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the PCM.
  7. If all circuits test normal, replace the IPC.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Control Module References for PCM replacement, setup, and programming
    •  Instrument Cluster Replacement