Removal Procedure
- Remove the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side .
- Disconnect the blower motor electrical connector.
- Remove the blower motor mounting screws.
- Remove the blower motor from the HVAC module assembly.
- Disconnect the electrical connector from the blower
motor control processor assembly.
- Remove the forward blower control processor mounting screws.
- Remove the rearward blower control processor mounting screw.
- Remove the blower control processor assembly from the
HVAC module assembly.
Installation Procedure
- Install the blower motor control processor assembly
to the HVAC module assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the rearward mounting screw.
Tighten
Tighten the screw to 1.8 N·m (16 lb in).
- Install the forward mounting screws.
Tighten
Tighten the screws to 1.8 N·m (16 lb in).
- Connect the electrical connector to the blower control
processor assembly.
- Install the blower motor to the HVAC module assembly.
- Install the blower motor mounting screws.
Tighten
Tighten the screws to 1.8 N·m (16 lb in).
- Connect the blower motor electrical connector.
- Install the right side I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side.