The number below refers to the step number on the diagnostic table.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or the heating is insufficient. | ||||||||||||||||
1 |
Important: The single C60 HVAC Manual air temperature control and the dual CJ3 HVAC Manual control is diagnosed in this table. Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||||
2 |
Does the blower motor operate in any of the speed positions? | -- | Go to Step 3 | Go to Blower Motor Inoperative | ||||||||||||
3 | Does the blower motor operate in each speed position? | -- | Go to Step 4 | Go to Blower Motor Malfunction | ||||||||||||
4 | Except for the blower motor speed, are all of the functions of the HVAC control module inoperative? | -- | Go to Step 13 | Go to Step 5 | ||||||||||||
5 | Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 6 | ||||||||||||
6 |
Does the A/C compressor operate? | -- | Go to Step 7 | |||||||||||||
7 |
Does the drive shaft of the air temperature actuator or actuators rotate? | -- | Go to Step 8 | Go to Step 9 | ||||||||||||
8 | Inspect the air temperature door of the air temperature actuator or actuators for the following conditions:
Did you find and correct the condition? | -- | Go to Step 22 | |||||||||||||
9 | Test the ignition 3 voltage circuit of the suspect air temperature actuator for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 10 | ||||||||||||
10 | Test the ground circuit of the suspect air temperature actuator or actuators for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 11 | ||||||||||||
11 | Test the door control circuit of the suspect air temperature actuator or actuators for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 12 | ||||||||||||
Important:: Ensure that the HVAC control module connector is connected during this step in order to avoid misdiagnosis.
Is the voltage measurement within the specified values with a smooth transition between cold and hot? | 0 V at cold 12 V at hot | Go to Step 17 | Go to Step 19 | |||||||||||||
13 | Test the ignition 3 voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 14 | ||||||||||||
14 | Test the battery positive voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 15 | ||||||||||||
15 | Test the blower motor control OFF circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 16 | ||||||||||||
16 | Test the ground circuit of the HVAC control module for an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 19 | ||||||||||||
17 | Inspect for poor connections at the harness connector of the air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 22 | Go to Step 18 | |||||||||||||
18 | Inspect the suspect air temperature actuator, door and any attaching linkage for binding or a condition that prevents drive shaft rotation. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 20 | ||||||||||||
19 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 21 | ||||||||||||
20 | Replace the air temperature actuator. Refer to Temperature Valve Actuator Replacement or Temperature Valve Actuator Replacement - Right Side or Temperature Valve Actuator Replacement - Left Side . Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||||||
21 | Replace the HVAC control module. Refer to Control Module References . Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |