Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | ||||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||||
2 |
Does the scan tool indicate that the recirculation switch changes state? | -- | Go to Step 3 | Go to Step 11 | ||||||||||||
3 |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 8 | ||||||||||||
4 | Test the low reference circuit of the recirculation actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 5 | ||||||||||||
5 |
Does the voltage measure near the specified value? | 0 V outside air | Go to Step 6 | Go to Step 7 | ||||||||||||
6 |
Does the voltage measure near the specified value? | 12 V recirc | Go to Step 9 | Go to Step 7 | ||||||||||||
7 | Test the recirculation door control circuit of the recirculation actuator for an open, a high resistance, a short to ground, or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 | ||||||||||||
8 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs . Did you complete the repair? | -- | Go to Step 14 | -- | ||||||||||||
9 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 10 | ||||||||||||
10 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 | ||||||||||||
11 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 | ||||||||||||
12 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||||
13 | Replace the HVAC control module. Refer to Control Module References . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||||||||
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |