GM Service Manual Online
For 1990-2009 cars only

Circuit Description

To control emissions of Hydrocarbons (HC), Carbon Monoxide (CO), and Oxides of Nitrogen (NOx), a three-way catalytic converter is used. The catalyst within the converter promotes a chemical reaction which oxidizes the HC and CO present in the exhaust gas, converting them into harmless water vapor and carbon dioxide. The catalyst also reduces NOx, converting it to nitrogen. The PCM has the ability to monitor this process using the HO2S 1 and the HO2S 2 heated oxygen sensors. The HO2S 1 sensor produces an output signal which indicates the amount of oxygen present in the exhaust gas entering the three-way catalytic converter. The HO2S 2 sensor produces an output signal which indicates the oxygen storage capacity of the catalyst; this in turn indicates the catalyst's ability to convert exhaust gases efficiently. If the catalyst is operating efficiently, the HO2S 1 signal will be far more active than that produced by the HO2S 2 sensor. If the PCM detects a level of HO2S 2 activity that indicates the catalyst is no longer operating efficiently, DTC P0420 will be set.

The PCM determines if the catalyst is ready for testing based on the following criteria:

    • Intake air temperature is greater than 0°C (32°F).
    • Engine Coolant Temperature is greater than 75°C (167°F).
    • Mass Air Flow is between 15 gm/s and 32 gm/s.
    • Engine load is less than 63% and steady.
    • Engine speed is less than 4000 RPM.
    • Above conditions for up to 4 minutes.

This ensures that the catalyst is sufficiently warmed up for testing purposes. Once these conditions have been met, the PCM can begin collecting the catalyst diagnostic test samples.

Conditions for Setting the DTC

    • No MAF sensor, TP sensor, HO2S, ECT sensor, MAP sensor, Idle speed, Fuel trim, EGR flow, EGR pintle position, EVAP purge, Crankshaft position sensor, Injector circuit, Misfire, IAT sensor or VSS DTC(s) are set.
    • The catalyst is ready for testing (refer to DTC P0420 Circuit Description).
    • Engine speed is between 1000 rpm and 3000 rpm.
    • Vehicle speed between 40 and 75 MPH.
    • The PCM determines that the catalyst's oxygen storage capacity is lower than a threshold considered acceptable.

Action Taken When the DTC Sets

    • The PCM will illuminate the malfunction indicator lamp (MIL) during the first trip in which the diagnostic test has been run and failed.
    • The PCM will store conditions which were present when the DTC set as Freeze Frame and Failure Records data.

Conditions for Clearing the MIL/DTC

    • The PCM will turn OFF the MIL during the third consecutive trip in which the diagnostic has been run and passed.
    • The History DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction.
    • The DTC can be cleared by using the scan tool.

Diagnostic Aids

Check for the following conditions:

    • Poor connection at the PCM. Inspect harness connectors for backed out terminals, improper mating, broken locks, improperly formed or damaged terminals, and poor terminal to wire connection.
    • Damaged harness. Inspect the wiring harness for damage.
    • If the harness appears to be OK, observe the display on the scan tool while moving connectors and wiring harnesses related to the sensor. A change in the display will indicate the location of the malfunction.

Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to be set occurs. This may assist in diagnosing the condition.

HO2S 1/ HO2S 2 Activity Test:

    • Ensure that the engine is fully warmed up.
    • Using a scan tool, monitor HO2S 1 and HO2S 2 displays in Park while using the scan tool IAC RPM control function to maintain a mass air flow of 10 gm/s.
    • Compare the amount of activity (frequency and amplitude) on HO2S 1 to the activity on HO2S 2 over a 30 second period.
    • If the amount of activity on HO2S 2 is nearly as great as the activity on HO2S 1, a problem exists; use the DTC P0420 diagnostic table. If much less activity is noted on HO2S 2, the system is functioning properly.

Notice:  A misfiring condition may damage the replacement three-way catalytic converter. Check for a misfiring condition. If a misfire is present, repair the misfiring condition before replacing the three-way catalytic converter.

The TWC Monitor Test Counter displayed on the scan tool may be used to monitor the progress of the TWC diagnostic. To complete the TWC diagnostic with a good catalyst, the counter must be allowed to increment to 49 samples and roll over to 0 at least once. A failed catalyst may require three or more 50 sample tests to report a failure.

Test Description

Number(s) below refer to the step number(s) on the Diagnostic Table:

  1. Difficulty completing the DTC P0420 test may be encountered in areas where test conditions cannot be maintained easily, especially in urban areas. To minimize the amount of driving required to complete the DTC P0420 test, use the following procedure:

  2. • Allow the engine to warm completely.
    • With the vehicle in Park, monitor mass air flow on the scan tool and hold part throttle to maintain a reading of over 12 gm/s for at least 2 minutes. This will achieve the warm catalyst requirement for running the test.
    • Operate the vehicle in second or third gear to remain in the DTC P0420 test conditions described in Conditions for Setting DTC as much as possible.
    • If you must stop the vehicle, maintain the warm catalyst criteria as follows:
  3. Place the vehicle in Park or Neutral.
  4. Hold part throttle to maintain a mass air flow reading of over 15 gm/s for the duration of the stop.
  5. • The TWC Monitor Test Counter display on the scan tool may be used to monitor the progress of the TWC diagnostic. To complete the TWC diagnostic, the counter must be allowed to increment to 49 and roll over to 0 at least once. With a failed TWC, the counter may have to increment to 49 and roll over to 0 three times or more.

DTC P0420 - TWC System Low Efficiency

Step

Action

Value(s)

Yes

No

1

Was the Powertrain On-Board Diagnostic (OBD) System Check performed?

--

Go to Step 2

Go to the Powertrain On Board Diagnostic (OBD) System Check

2

Are any other DTC(s) set?

--

Diagnose the other DTC first - Go to Powertrain Control Module Diagnosis

Go to Step 3

3

  1. Visually and physically inspect the three-way catalytic converter for damage.
  2. Check for the following:
  3. • Dents.
    • Severe discoloration caused by excessive temperatures.
    • Holes.
    • Internal rattle caused by damaged catalyst substrate.
  4. Also, ensure that the three-way catalytic converter is a proper original equipment manufacturer part.

Did your inspection reveal a problem?

--

Go to Step 6

Go to Step 4

4

  1. Visually and physically inspect the exhaust system for leaks, damage, and for loose or missing hardware.
  2. If a problem is found, repair as necessary.

Did your inspection reveal a problem?

--

Go to Step 7

Go to Step 5

5

  1. Visually and physically inspect HO2S 1 and HO2S 2. Ensure that HO2S 1 and HO2S 2 are secure and that the pigtails and wiring harness are not contacting the exhaust pipe or otherwise damaged.
  2. If a problem is found, repair as necessary. Refer to Heated Oxygen Sensor (O2S) Repair in Electrical Diagnosis.

Did your inspection reveal a problem?

--

Go to Step 7

Go to Step 6

6

Replace the three-way catalytic converter. Refer to Exhaust System.

Notice:  A misfiring condition may damage the replacement three-way catalytic converter. Check for a misfiring condition. If a misfire is present, repair the misfiring condition before replacing the three-way catalytic converter.

Is action complete?

--

Go to Step 7

--

7

  1. Review and record the scan tool Fail Records data.
  2. Clear DTC P0420.
  3. Start the engine and allow it to warm up until the Engine Coolant Temperature monitored on the scan tool is greater than the first specified value.
  4. Run the engine to maintain Mass Air Flow range at the second specified value for at least 2 minutes.
  5. Using a scan tool, monitor TWC Monitor Test Counter while operating the vehicle to maintain DTC P0420 test conditions. Refer to Test Description .
  6. Continue operating the vehicle until the TWC Monitor Test Counter reaches 49 and returns to 0 at least once.
  7. Select scan tool Specific DTC information for DTC P0420.

Note test result; does scan tool indicate DTC P0420 Test Ran and Passed?

75°C (167°F)

12-15 gm/s

System OK

Go to Step 2