Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the entire Exterior Lights System Check? | -- | Go to Step 2 | |
2 |
Is battery voltage measured? | B+ | Go to Step 3 | Go to Step 5 |
3 |
Do the left turn lamps light? | -- | Go to Step 4 | Go to Step 6 |
4 | Replace the turn signal flasher. Is the repair complete? | -- | -- | |
5 | Repair the open or the short to ground in CKT 539 (PNK). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Test CKT 16 (PPL) for an open or short to ground. Refer to Testing for Continuity or Testing for Short to Ground in Wiring Systems. Is CKT 16 OK? | -- | Go to Step 7 | Go to Step 8 |
7 | Replace the turn/hazard switch assembly. Is the repair complete? | -- | -- | |
8 | Repair the suspect wiring. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |