Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate the ignition switch closed with the key in and open with the key out of the ignition switch? | -- | Go to Step 4 | Go to Step 3 |
3 | Inspect CKT 80 (LT GRN) for a short to ground between the ignition switch and the remote function actuator (RFA) module. Was a short to ground found? | -- | Go to Step 6 | Go to Step 5 |
4 | Inspect CKT 653 (DK BLU/WHT) for a short to ground between the RFA module and the body control module (MALL). Was a short to ground found? | -- | Go to Step 6 | Go to Step 7 |
5 | Replace the ignition switch. Is the replacement complete? | -- | -- | |
6 | Repair the affected wiring. Is the repair complete? | -- | -- | |
7 | Disconnect the RFA module. Did the chime stop? | -- | Go to Step 8 | Go to Step 9 |
8 | Replace the RFA module. Is the replacement complete? | -- | -- | |
9 | Replace the MALL. Is the replacement complete? | -- | -- |