Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the measured voltage equal the specified value? | 12 V | Go to Step 5 | Go to Step 3 |
3 | Inspect CKT 99 (BLK) for a open or short to ground. Is the wiring OK? | -- | Go to Step 6 | Go to Step 4 |
4 | Repair the wiring in CKT 99 (BLK). Is the repair complete? | -- | -- | |
5 | Measure the voltage between the connector terminal B (BLK) and the connector terminal A (BLK). Does the measured voltage equal the specified value? | 12 V | Go to Step 11 | Go to Step 8 |
6 | Inspect the instrument cluster connector C1 for proper terminal contact. Is the terminal OK? | -- | Go to Step 15 | Go to Step 14 |
7 | Replace the instrument cluster. Is the repair complete? | -- | -- | |
8 | Inspect CKT 1350 (BLK) for a open. Is the wiring OK? | -- | Go to Step 10 | Go to Step 9 |
9 | Repair the wiring in CKT 1350 (BLK). Is the repair complete? | -- | Go to Step 10 | -- |
10 | Inspect the in-line connector C105 for proper terminal contact. Is the terminal OK? | -- | -- | |
11 | Inspect the windshield washer solvent level switch connector for proper terminal contact. Is the terminal OK? | -- | Go to Step 12 | Go to Step 13 |
12 | Replace the washer fluid level switch. Is the repair complete? | -- | -- | |
13 | Repair the windshield washer solvent level switch connector terminals. Is the repair complete? | -- | -- | |
14 | Repair the poor connection. Is the repair complete? | -- | -- | |
15 | Inspect the in-line connector C105 for proper terminal contact. Are the terminals OK? | -- | Go to Step 7 | Go to Step 14 |