Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Windows System Check? | -- | Go to Step 2 | |
2 |
Is the voltage within the specified range? | 10-15 V | Go to Step 4 | Go to Step 3 |
3 | Repair an open in CKT 141 (BRN). Refer to Wiring Repairs in Wiring systems. Did you complete the repair? | -- | -- | |
4 |
Is the voltage within the specified range? | 10-15 V | Go to Step 6 | Go to Step 5 |
5 | Repair an open in CKT 164 (DK BLU). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
6 |
Is the spring winding correctly? | -- | Go to Step 8 | Go to Step 7 |
7 | Rewind the counterbalance spring. Refer to Power Windows Circuit Description . Did you complete the repair? | -- | -- | |
8 | Replace the express down module. Did you complete the repair? | -- | -- |