The body control module (MALL) provides a set of internal service diagnostic features. These features assist the technician in troubleshooting electrical short conditions that may affect the module. If an electrical short occurs during vehicle operation, the MALL module stores one or more codes. These codes are known as history codes. History codes may be accessed by entering the MALL module diagnostic mode. After providing the history codes, the MALL module enters the Input/Output (I/O) Mode. The I/O Mode provides the technician with the ability to verify that the inputs to the MALL module are functioning properly.
In order to enter the body control module (MALL) diagnostic mode perform the following steps:
In order to exit the diagnostic mode, perform 1 of the following actions:
• | Turn the ignition switch to the OFF position. |
• | Accelerate the vehicle to at least 13 km/h (8 mph). |
Upon entering the diagnostic mode, the MALL module provides audible feedback in the form of tones. The number of tones represents the stored history code number. The FASTEN BELTS indicator flashes with each tone. In the following chart, the history code is listed with the corresponding short circuit condition:
History Code | Short Condition |
---|---|
1 | FASTEN BELTS indicator (SBTELL) circuit |
2 | Battery protection (PBATT) circuit |
3 | Courtesy lamps (CTSY) circuit |
The MALL module cycles through the stored history code(s) 3 times. For example, if a short condition occurs on the FASTEN BELTS indicator circuit and battery protection circuit, one tone sounds for the FASTEN BELTS indicator circuit, followed by 2 tones for the battery protection circuit. A 2 second pause occurs before the history codes repeat. If no history codes exist, the MALL module immediately enters the input/output mode.
The history codes may be erased by holding down the power door unlock switch for 4 seconds.
While in the input/output (I/O) mode, the technician may test each input to the MALL module by activating/deactivating its input device (the door latch switch, interior lamp switch, seatbelt switch, etc.) The MALL module provides feedback on each input transition in the form of a single tone along with a simultaneous flash of the FASTEN BELTS indicator.
Test the battery protection (PBATT) input/output by cycling the interior lamps switch. The first cycle (OFF, ON, OFF) deactivates the PBATT output (interior lamps off). Cycling the interior lamp switch again activates the PBATT output (interior lamps on). The cycle repeats afterwards.
When using the keyless entry transmitter, the audible feedback is different when actuating the following items:
• | The power door lock switch |
• | The transaxle gear selector |
• | The keyless entry unlock, using the transmitter |
The following chart describes the feedback for this case:
Input | MALL Module Audible Feedback | Reason |
---|---|---|
Power Door Lock Switch | 2 Tones | 350 ms pulse from the remote function actuator (RFA) module |
PARK Transition | 2 Tones | 350 ms pulse from the RFA module due to the gear selector power door lock/unlock feature |
Remote Unlock (Using Transmitter) | 2 Tones | 350 ms pulse from the RFA module due to remote interior illumination feature |
The following table lists the MALL inputs and outputs that should be evaluated during the input/output (I/O) mode:
Function / Feature | Test by Activating / Deactivating |
---|---|
Auxiliary Chime | Park Brake and/or Instrument Cluster Warning |
Interior Lamps | Interior Lamp Switches |
Dome Lamps | Dome Lamp Switches |
Door Latch (Jamb) Switches | Left and Right Front Door Latch (Jamb) Switches |
Power Door Locks | Power Door Lock and Unlock Switches |
Automatic Door Lock and Unlock | Gear Selector |
Battery Protection | Interior Lamp Switch |
Lamps On Reminder Chime | Headlamp Switch |
Fasten Seatbelts Chime and FASTEN BELTS indicator | Driver's Seatbelt Switch |
Turn Signal On Reminder Chime | Left and Right Turn Signal |
Trunk Lid Ajar Lamp | Trunk Lid Latch Switch |