Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Is the voltage equal to the specified value? | 12 V | Go to Step 5 | Go to Step 3 |
3 | Inspect CKT 746 (BLK/WHT) for an open or a short to ground. Is there an open or a short to ground in CKT 746? | -- | Go to Step 4 | Go to Step 6 |
4 | Repair the open or the short to ground in CKT 746. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
5 | Measure the voltage between the lock actuator connector terminal C (BLK/WHT) and terminal A (BLK/WHT). Is the voltage equal to the specified value? | 12 V | Go to Step 10 | Go to Step 8 |
6 | Inspect the instrument cluster connector C2 terminal B4 for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 7 | Go to Step 12 |
7 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Did you complete the repair? | -- | -- | |
8 | Inspect CKT 151 (BLK/WHT) for an open. Is there an open in CKT 151? | -- | Go to Step 9 | |
9 | Repair the open in CKT 151. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |
10 | Inspect the right front door lock actuator connector for proper terminal contact. Is the connector terminal contact OK? | -- | Go to Step 11 | Go to Step 12 |
11 | Replace the right front door lock actuator. Refer to Door Lock Actuator Replacement in Doors. Did you complete the repair? | -- | -- | |
12 | Repair the faulty terminal contact. Refer to Connector Repairs in Wiring Systems. Did you complete the repair? | -- | -- |