The HVAC programmer commands the actuator to move by suppling battery voltage. The feedback supplied to the HVAC programmer is a regulated 5 volts. The feedback voltage is a function of the motor position with a high voltage of 4-5 volts indicating full cold door position. A low voltage of less than 1 volt indicates the full hot position. Operation of the air mix door actuator can be evaluated through the Scan Tool .
The ignition is ON.
Only the full hot or full cold may be used by the system.
• | Using a Scan Tool . |
• | A history DTC will clear when 40 consecutive ignition cycles have occurred without a malfunction. |
• | HVAC programmer battery voltage is interrupted. |
This test allows the Scan Tool to command the actuators to determine that proper movement is being achieved.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check | ||||||
2 |
Exercise the mode actuator to COM High and to COM Low. Are the values within the specified ranges? | COM High 203 COM Low 10 | Go to Step 4 | Go to Step 3 | ||||||
3 | Replace the heater and A/C programmer. Refer to Programmer Replacement . Did you complete the repair? | -- | Go to Step 22 | -- | ||||||
4 |
Are the values within the specified ranges? | ACT High 188-201 ACT Low 51-60 | Go to Step 3 | Go to Step 5 | ||||||
5 |
Does the mode actuator respond correctly? | -- | Go to Step 7 | Go to Step 12 | ||||||
6 | Test the mode actuator to programmer sense circuit for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 9 | ||||||
7 |
Refer to Measuring Voltage in Wiring Systems. Does the voltage measure near the specified value? | 5 V | Go to Step 6 | Go to Step 8 | ||||||
8 | Test CKT 705 (GRY) between the mode actuator connector pin 10 and the programmer connector C1 terminal A1 for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 3 | ||||||
9 | Measure the resistance between the mode actuator connector pin 7 and pin 10. Refer to Testing for Continuity in Wiring Systems. Does the resistance measure near the specified value? | 8.5 ohms | Go to Step 10 | Go to Step 11 | ||||||
10 | Measure the resistance between the mode actuator connector pin 7 and pin 9. Refer to Testing for Continuity in Wiring Systems. Does the resistance measure within the specified range? | 1.7-7.5 ohms | Go to Step 3 | Go to Step 11 | ||||||
11 | Replace the mode actuator. Refer to Mode Actuator Replacement . Did you complete the repair? | -- | Go to Step 22 | -- | ||||||
12 |
Refer to Measuring Voltage in Wiring Systems. Does the voltage measure near the specified value? | 10 - 15 V | Go to Step 15 | Go to Step 13 | ||||||
13 | Test CKT 541 (BRN) between the IP fuse block flat pack MTR fuse and mode actuator connector pin 5 for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 14 | ||||||
14 | Test CKT 695 (GRY/BLK) between the programmer connector C1 terminal A7 and the mode actuator connector terminal 7 for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 15 | ||||||
15 | Test for voltage between the air mix #1 connector terminal 7 and terminal 10. Does the voltage measure near the specified value? | 5 V | Go to Step 17 | Go to Step 16 | ||||||
16 | Test CKT 705 between the programmer connector C1 terminal A1 and the mode actuator connector terminal 10 for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 17 | ||||||
17 |
Refer to Measuring Voltage in Wiring Systems. Does the voltage measure near the specified value? | 2.5 V | Go to Step 19 | Go to Step 18 | ||||||
18 | Test the enable circuit between the programmer and the mode actuator connector for the following conditions:
Refer to Intermittents and Poor Connections Diagnosis or Testing for Continuity or Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 3 | ||||||
19 |
Does the voltage measure near the specified values when the proper function is exercised? | 0 V OFF 5 V ON | Go to Step 20 | Go to Step 3 | ||||||
20 |
Does the door move freely through the full range of travel? | -- | Go to Step 11 | Go to Step 21 | ||||||
21 | Repair the door of the mode actuator as needed. Did you complete the repair? | -- | Go to Step 22 | -- | ||||||
22 | Using the scan tool clear all the DTCs. Does the DTC reset? | -- | Go to Step 2 | Go to Diagnostic System Check |