Table 1: | Pontiac and Oldsmobile w/o Outside Recirculated Air Option |
Table 2: | Outside Recirculated Air Option (Oldsmobile Only) |
Perform the Functional Test and the diagnostic tests in order to verify the following systems:
• | Air conditioning |
• | Electrical |
• | Vacuum |
• | Refrigeration |
Control Settings | System Response | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fan Switch | Mode Switch | A/C Push Button | A/C Signal | A/C Indicator | Comments | |||||||||
ON | U, B, L | OFF | LOW | OFF | The A/C signal and the A/C indicator are on according to the position of the push button when the mode switch is in any of the following positions:
| |||||||||
ON | U, B, L | OFF | LOW | OFF | ||||||||||
ON | U, B, L | ON | HIGH | ON | ||||||||||
ON | U, B, L | ON | HIGH | ON | ||||||||||
ON | M, BL, DF | OFF (3) | HIGH (1) | OFF | When in Max (Pontiac Only), Blend or Defrost mode, the following conditions occur:
| |||||||||
ON | M, BL, DF | OFF (3) | HIGH (1) | OFF | ||||||||||
ON | M, BL, DF | ON (3) | HIGH | ON | ||||||||||
ON | M, BL, DF | ON (3) | HIGH | ON | ||||||||||
OFF | U, B, L | (2) | LOW (1) | OFF | When the fan switch is OFF, the following conditions occur:
| |||||||||
OFF | U, B, L | (2) | LOW (1) | OFF | ||||||||||
OFF | BL, DF | (2) | LOW (1) | OFF | ||||||||||
1. Default Condition 2. Not Allowed 3. Previous Switch State | ||||||||||||||
M-Max (Pontiac Only) U-Upper B-Bi-Level L-Lower BL-Blend DF-Defrost |
Control Settings | System Response | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fan Switch | Mode Switch | A/C Push Button | OSA/REC Push Button | Recirculation Vacuum | Recirculation Indicator | OSA Indicator | Comments | ||||||
ON | U, B, L | OFF | OSA | OFF | OFF | ON | The vacuum and the indicators are ON according to the position of the push buttons when the mode switch is in any of the following positions:
| ||||||
ON | U, B, L | OFF | RECIRC | ON | ON | OFF | |||||||
ON | U, B, L | ON | OSA | OFF | OFF | ON | |||||||
ON | U, B, L | ON | RECIRC | ON | ON | OFF | |||||||
ON | BL, DF | OFF (3) | OSA | OFF | OFF | ON | The vacuum defaults to OFF and the OSA indicator is lit when the mode switch is in the following settings:
| ||||||
ON | BL, DF | OFF (3) | RECIRC (2) | OFF (1) | OFF | ON | |||||||
ON | BL, DF | ON (3) | OSA | OFF | OFF | ON | |||||||
ON | BL, DF | ON (3) | RECIRC (2) | OFF (1) | OFF | ON | |||||||
OFF | U, B, L | (2) | OSA | OFF | OFF | ON | When the fan switch is OFF, the vacuum and the indicators follow the settings according to the position of the push buttons. | ||||||
OFF | U, B, L | (2) | RECIRC | ON | ON | OFF | |||||||
OFF | BL, DF | (2) | (2) | OFF (1) | OFF | ON | |||||||
1. Default Condition 2. Not Allowed 3. Previous Switch State | |||||||||||||
U-Upper B-Bi-Level L-Lower BL-Blend DF-Defrost |