Diagnostic Instructions
DTC Descriptors
• | DTC B0109 Left Rear Side Deployment Loop Resistance Low |
• | DTC B0110 Left Rear Side Deployment Loop Open |
• | DTC B0111 Left Rear Side Deployment Loop Voltage Out of Range |
Diagnostic Fault Information
Circuit
| Short to Ground
| Low Resistance
| High Resistance
| Open
| Short to Voltage
|
Side Impact Module - Left Rear - Low Control
| --
| --
| B0110, B0111
| B0110
| B0111
|
Side Impact Module - Left Rear - High Control
| B0111
| B0109
| B0110, B0111
| B0110
| B0111
|
Circuit Description
The driver side deployment loop consists of the following components:
• | An inflatable restraint side impact module LR |
• | The side impact module LR high circuits |
• | The side impact module LR low circuits |
A shorting bar is used within the side impact module LR connector. The shorting bar will short together the side impact module LR high circuit and the side impact module LR low circuit when the connector is disconnected. This helps prevent unwanted deployment
of the inflator module during servicing. During a side or frontal crash of sufficient force, the inflatable restraint sensing and diagnostic module (SDM) will allow current to flow through the deployment loop. This flow of current will deploy the side impact
module LR. The SDM performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a DTC will be stored in memory.
Conditions for Running the DTC
Ignition 1 voltage is within the normal operating voltage range.
Conditions for Setting the DTC
DTC B0109
The SDM detects the LR side impact module deployment loop resistance is less than 1.3 ohms for 500 milliseconds.
DTC B0110
• | The SDM detects the LR side impact module deployment loop resistance is greater than 4.8 ohms for 500 milliseconds. |
• | The SDM detects the voltage at the LR side impact module high control is less than 2.4 volts and LR side impact module deployment loop resistance is 6 ohms or greater for 500 milliseconds. |
DTC B0111
• | The SDM detects the voltage at the LR side impact module high control is greater than 6 volts for 500 milliseconds. |
• | The SDM detects the voltage at the LR side impact module high control is less than 2.4 volts and the LR side impact module deployment loop resistance is less than 6 ohms for 500 milliseconds. |
Action Taken When the DTC Sets
The SDM requests the instrument panel cluster (IPC) to illuminate the AIR BAG indicator.
Conditions for Clearing the DTC
• | The condition for setting the DTC no longer exists. |
• | A history DTC will clear once 255 malfunction-free ignition cycles have occurred. |
Reference Information
Schematic Reference
SIR Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
SIR System Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for scan tool information
Special Tools
Circuit/System Testing
Important: Refer to
SIR Service Precautions. When removing connectors inspect for damage or corrosion. Damage or corrosion in the following requires repair or replacement of the affected
component/connector.
• | Inflatable restraint side impact module |
• | Inflatable restraint side impact module wiring harness connector |
• | SDM wiring harness connector |
- Ignition OFF, disconnect the harness connector at the LR inflatable restraint side impact module.
- With the appropriate adaptor, connect
J 38715-A
in place of the inflatable restraint side impact module.
- Ignition ON, verify the DTC is set as current.
⇒ | If DTC is not set or is set as history, replace the inflatable restraint side impact module. |
- Ignition OFF, disconnect
J 38715-A
and the adaptor. Disconnect the harness connector at the SDM.
- Ignition ON, test for less than 1 volt between the high control circuit terminal 25 and ground.
⇒ | If greater than the specified range, test the high control circuit for a short to voltage. |
- Test for less than 1 volt between the low control circuit terminal 24 and ground.
⇒ | If greater than the specified range, test the low control circuit for a short to voltage. |
- Ignition OFF, test for infinite resistance between the high control circuit terminal 25 and ground.
⇒ | If less than the specified value, test the control circuit for a short to ground. |
- Test for infinite resistance between the appropriate low control circuit terminal 24 and ground.
⇒ | If less than the specified value, test the control circuit for a short to ground. |
- Test for less than 1 ohm on the high control circuit between the impact module terminal A and the SDM terminal 25.
⇒ | If greater than the specified range, test the control circuit for an open/high resistance. |
- Test for less than 1 ohm on the low control circuit between the impact module terminal B and the SDM terminal 24.
⇒ | If greater than the specified range, test the control circuit for an open/high resistance. |
- If all circuits test normal, replace the SDM.
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.