Subject: | No Reverse Condition (Replace Torque Convertor Clutch (TCC) Pulse Width Modulator (PWM) Solenoid) |
Models: | 2003 Cadillac CTS Built Prior to May 2003 |
with 5L-40-E Automatic Transmission (RPO M82) Built Prior to Transmission Serial Number 849522 (February 10, 2003) |
This bulletin is being revised to eliminate the Diagnostic Trouble Code information. Please discard Corporate Bulletin Number 03-07-30-024 (Section 07-Transmission/Transaxle)
Some customers may comment on a no reverse condition.
The cause may be an internal fault in the TCC PWM solenoid.
Follow the service procedure below for diagnosis and repair.
• | If the transmission fluid has signs of overheating and/or a burnt smell, the transmission is going to require internal repairs. Refer to Transmission Fluid Checking Procedure, SI Document ID #856433. |
• | If the transmission fluid is "normal" color and no burnt odor, continue with the next step. |
Important: Loosen, DO NOT REMOVE the valve body bolts and manual shift detent bolt.
Important:
• The "2690" TCC PWM solenoid is the suspect solenoid and should
NOT BE REUSED. • The new TCC PWM solenoid, P/N 96042599, is labeled "7792"
and should be the ONLY solenoid used.
Important: If the bolts are tightened at random, valve bores may become distorted and inhibit proper valve operation.
Tighten
• | Tighten the 8 inverted TORX® valve body bolts to 11 N·m (97 lb in). |
• | Tighten the manual shift detent spring bolt to 11 N·m (97 lb in). |
Important: Fluid pan gaskets are reusable. Replace the gasket ONLY if the sealing surface is damaged.
Important: The oil drain plug and oil fill plug must be inspected for damage to the threads or O-rings before reinstalling. If damage is found, replace with a new plug.
Tighten
Tighten the fluid drain plug to 20 N·m (15 lb ft).
Part Number | Description | Qty |
---|---|---|
96042599 | Solenoid, TCC PWM (Labeled 7792) | 1 |
Parts are currently available from GMSPO.
For vehicles repaired under warranty, use:
Labor Operation | Description | Labor Time |
---|---|---|
K6557 | Wiring Harness And/Or Solenoid - Pressure Control Solenoid - Replace | 1.0 hr* |
*This labor time is for bulletin use ONLY. |