When you turn the ignition switch to the ON position, the control module enables the fuel pump relay, which in turn powers the fuel pump. The fuel pump remains ON as long as the engine is cranking or running and the control module receives ignition reference pulses. If there are no ignition reference pulses, the control module shuts the fuel pump OFF within 2 seconds after the ignition was switched to the ON position, or if the engine stops.
The fuel tank stores the fuel supply. The fuel pump is an electric pump that is attached to the primary fuel tank module assembly. The fuel pump also supplies fuel to the siphon jet pump, also attached to the primary fuel tank module. The siphon jet pump draws fuel from the secondary side of the fuel tank to the primary side of the fuel tank. The fuel pump is designed to provide fuel at a pressure above the pressure that is needed by the fuel injectors. A fuel pressure regulator, which is also located in the fuel tank, is attached to the primary fuel tank module. The fuel pressure regulator keeps the fuel available to the fuel injectors at a regulated pressure. The port on the fuel pressure regulator is an atmospheric vent. The fuel pressure regulator does not compensate for changes in intake manifold vacuum. Unused fuel is returned from the fuel filter to the fuel tank by a separate fuel return pipe.
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that the fuel pump is operating.
This step verifies that the vehicle is not out of fuel. If the right fuel sender is below 0.8-volt, and the left fuel sender is above 0.8-volt, a fuel transfer condition exists.
This step tests for an internal fuel leak. If the fuel pressure drops during this test, then an internal loss of pressure is indicated.
This step isolates the condition. Replace the primary fuel tank module assembly, if the fuel pressure remains constant, after closing the valve on the fuel pipe shut-off adapter. Locate and replace the leaking fuel injector if the pressure continues to decrease after closing the valve on the adapter.
This step isolates the condition. Replace the primary fuel tank module assembly for a stuck open or leaking fuel pressure regulator, if the fuel pressure increases above the specified value.
This step verifies that a circuit condition is not the cause of a fuel pressure concern. Inspect all fuel pump electrical circuits thoroughly.
Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Fuel Hose/Pipes Routing Diagram | ||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||||
Important: Inspect the fuel system for the following conditions before proceeding with this diagnostic procedure:
Does the fuel pump operate? | -- | Go to Step 3 | ||||||||||||
3 | Observe the fuel level sensor left voltage with a scan tool. Is the fuel level sensor left voltage less than the specified value? | 0.8 V | Go to Step 4 | Go to Step 6 | ||||||||||
Observe the fuel level sensor right voltage with a scan tool. Is the fuel level sensor right voltage less than the specified value? | 0.8 V | Go to Step 5 | Go to Step 14 | |||||||||||
5 |
Do any of the scan tool parameters indicate a lean condition? | 19 L (5 gal) | Go to Step 15 | |||||||||||
6 |
Important:
Is the fuel pressure within the specified range? | 380-427 kPa (55-62 psi) | Go to Step 7 | Go to Step 11 | ||||||||||
Important: The fuel pressure will drop when the fuel pump stops operating. After the fuel pump stops operating, the fuel pressure should stabilize and remain constant.
Does the fuel pressure decrease by more than the specified value? | 34 kPa (5 psi) | Go to Step 10 | Go to Step 8 | |||||||||||
8 |
Does the fuel pressure decrease by more than the second specified value? | 69 kPa (10 psi) 14 kPa (2 psi) | Go to Step 19 | Go to Step 9 | ||||||||||
9 |
Do any of the scan tool parameters indicate a lean condition? | -- | Go to Step 15 | |||||||||||
Does the fuel pressure remain constant? | -- | Go to Step 19 | Go to Step 18 | |||||||||||
11 | Is the fuel pressure more than the specified value? | 410 kPa (60 psi) | Go to Step 12 | Go to Step 13 | ||||||||||
12 | Inspect the fuel return hose/pipe for a restriction. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 19 | ||||||||||
Does the fuel pressure increase to more than the specified value? | 380-427 kPa (55-62 psi) | Go to Step 19 | Go to Step 15 | |||||||||||
14 |
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 19 | ||||||||||
15 | Inspect the following components for a restriction:
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 16 | ||||||||||
Inspect the harness connectors and ground circuits of the fuel pump for poor connections. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 17 | |||||||||||
17 |
Did you find and correct the condition? | -- | Go to Step 20 | Go to Step 19 | ||||||||||
18 |
Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||
19 | Replace the primary fuel tank module. Refer to Primary Fuel Tank Module Replacement . Did you complete the replacement? | -- | Go to Step 20 | -- | ||||||||||
20 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |