The automatic transmission fluid temperature (TFT) sensor is a negative coefficient thermistor. When the transmission fluid is cold, the sensor resistance is high. As the transmission fluid warms up, the sensor resistance decreases. This diagnostic monitors the TFT circuit. The circuit may be functional, but not in the normal operating range. This diagnostic indicates stuck, erratic, intermittent, skewed, or inaccurate values, indicating poor system performance. The TFT range is -40 to +151°C (-40 to +305°F).
If the TCM detects rapid or no voltage changes in the TFT sensor circuit, then DTC P0711 sets. DTC P0711 is a type C DTC.
This diagnostic procedure supports the following DTC:
DTC P0711 Transmission Fluid Temperature (TFT) Sensor Performance
• | No ECT DTC P0115. |
• | No ISS DTCs P0716 or P0717. |
• | No OSS DTCs P0722 or P0723. |
• | DTC P0711 has not passed in the current ignition cycle. |
• | The engine run time is greater than 5 seconds. |
• | The transmission fluid temperature is -39 to +149°C (-38 to +300°F). |
• | For conditions 1 and 2 below, the engine coolant temperature is greater than 70°C (158°F) and has changed by at least 50°C (90°F) since startup. |
• | For conditions 1 and 2 below, the TCC slip speed is 120 RPM or greater for 600 seconds (10 minutes) cumulatively. |
One of the following conditions occurs:
• | The transmission fluid temperature at startup is -40 to +21°C (-40 to +70°F). |
• | The vehicle speed is greater than 8 km/h (5 mph) for 900 seconds (15 minutes) cumulatively. |
• | The transmission fluid temperature has not changed by more than 2°C (4°F) since startup for 100 seconds (1 minute and 40 seconds). |
• | The transmission fluid temperature at startup is 129-150°C (264-302°F). |
• | The vehicle speed is greater than 8 km/h (5 mph) for 600 seconds (10 minutes) cumulatively. |
• | The transmission fluid temperature has not changed by more than 2°C (4°F) since startup for 100 seconds (1 minute and 40 seconds). |
The transmission fluid temperature has changed by 20°C (36°F) or greater within 250 milliseconds; 14 times within 7 seconds.
• | The TCM does not request the engine control module (ECM) to illuminate the malfunction indicator lamp (MIL). |
• | The TCM freezes transmission adaptive functions. |
• | The TCM calculates a default transmission fluid temperature based on engine coolant temperature, intake air temperature and engine run time. |
• | The TCM records the operating conditions when the Conditions for Setting the DTC are met. The TCM stores this information as a Failure Record. |
• | The TCM stores DTC P0711 in TCM history. |
• | A scan tool can clear the DTC. |
• | The TCM clears the DTC from TCM history if the vehicle completes 40 warm-up cycles without a non emission related diagnostic fault occurring. |
• | The TCM cancels the DTC default actions when the fault no longer exists and the DTC passes. |
The numbers below refer to the step numbers on the diagnostic table.
This step tests for an intermittent short or open condition in the engine wiring harness. The test light is used as a resistor in the circuit.
This step determines if the TCM or the TFT, sensor is causing a steady, unchanging TFT, reading.
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information | ||||||||
2 | Perform the Transmission Fluid Checking Procedure. Refer to Transmission Fluid Check . Did you perform the Transmission Fluid Checking Procedure? | -- | Go to Step 3 | Go to Transmission Fluid Check | ||||||||
3 |
Important:
Did either of the conditions occur? | -- | Go to Step 4 | Go to Intermittent Conditions in Engine Controls - 3.6L (LY7) | ||||||||
4 | Did the scan tool display a condition in which the Trans. Fluid Temp. does not change by greater than the specified value in 1 minute and 40 seconds since startup? | 2°C (4°F) | Go to Step 6 | Go to Step 5 | ||||||||
Does the Trans. Fluid Temp. change by greater than the specified value? | 20°C (36°F) | Go to Step 7 | Go to Step 8 | |||||||||
Did the scan tool display a condition in which the Trans. Fluid Temp. does not change by greater than the specified value in 1 minute and 40 seconds since startup? | 2°C (4°F) | Go to Step 9 | Go to Step 8 | |||||||||
7 |
Refer to Testing for Continuity and Testing for Short to Ground in Wiring Systems. Did you find and correct a condition? | -- | Go to Step 10 | Go to Step 8 | ||||||||
8 | Replace the automatic transmission wiring harness. Refer to Transmission Internal Electrical Harness Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- | ||||||||
9 | Replace the TCM. Refer to Control Module References in Computer/Integrating Systems for replacement, set-up and programming. Did you complete the replacement? | -- | Go to Step 10 | -- | ||||||||
10 | Perform the following procedure in order to verify the repair:
Has the test run and passed? | -- | Go to Step 11 | Go to Step 2 | ||||||||
11 | With the scan tool, observe the stored information, capture info and DTC info. Does the scan tool display any DTCs that you have not diagnosed? | -- | Go to Diagnostic Trouble Code (DTC) List - Vehicle in Vehicle DTC Information | System OK |