Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics and Door Control Module Schematics in Doors Connector End View Reference: Master Electrical Component List in Wiring Systems | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 |
Important: The sunload sensor assembly must indicate low light conditions for the interior lamps to operate.
Do the courtesy lamps operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the Photocell voltage change? | Go to Step 4 | |
4 | With a scan tool command the Courtesy Lamp 1, 2 w/o dim output ON from the rear integration module (RIM) Output Control data list. Do all of the interior courtesy lamps turn ON? | Go to Step 6 | Go to Step 5 |
5 | Are all of the interior courtesy lamps inoperative? | Go to Step 10 | Go to Step 14 |
6 |
Does the scan tool display ON? | Go to Step 7 | Go to Step 8 |
7 |
Does the scan tool display ON for all the door jamb sw. inputs? | Go to Step 37 | Go to Step 9 |
8 |
Does the scan tool display ON? | Go to Step 25 | Go to Step 15 |
9 |
Does the scan tool display ON for the inoperative door jamb sw. input? | Go to Step 23 | Go to Step 17 |
10 |
Does the test lamp illuminate? | Go to Step 11 | Go to Step 30 |
11 | Probe the interior lamp relay switch side supply voltage circuit with a test lamp that is connected to a good ground. Does the test lamp illuminate? | Go to Step 12 | Go to Step 29 |
12 |
Does the test lamp turn ON and OFF with each command? | Go to Step 13 | Go to Step 21 |
13 |
Do the interior lamps illuminate? | Go to Step 22 | Go to Step 19 |
14 |
Does the test lamp illuminate? | Go to Step 28 | Go to Step 19 |
15 | Test the courtesy lamp switch on signal circuit for high resistance, open or short to power. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 16 |
16 | Test the interior lamp switch ground circuit for high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 26 |
17 | Test the inoperative door open switch signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 18 |
18 | Test the inoperative door open switch ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 24 |
19 | Test the interior lamp supply voltage circuit for an open, high resistance or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 20 |
20 | Test the courtesy lamp control circuit for an open or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 27 |
21 | Test the relay control circuit for a high resistance, an open or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 27 |
22 | Inspect for poor connections at the INT lamp relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 31 |
23 | Inspect for poor connections at the harness connector of the inoperative door lock actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 32 |
24 | Inspect for poor connections at the harness connector of the inoperative door control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 33 |
25 | Inspect for poor connections at the harness connector of the I/P dimmer switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 34 |
26 | Inspect for poor connections at the harness connector of the DIM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 35 |
27 | Inspect for poor connections at the harness connector of the RIM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 36 |
28 | Inspect for poor connections at the inoperative courtesy lamp bulb. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 38 | Go to Step 37 |
29 | Repair the open, high resistance or short to ground in the switch side supply voltage circuit of the INT lamp relay. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 38 | -- |
30 | Repair the high resistance or open in the control side supply voltage circuit of the INT lamp relay. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 38 | -- |
31 | Replace the in INT lamp relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the replacement? | Go to Step 38 | -- |
32 | Replace the inoperative door lock actuator. Refer to Front Side Door Latch Replacement or Rear Side Door Latch Replacement in Doors. Did you complete the replacement? | Go to Step 38 | -- |
33 | Replace the inoperative door module. Refer to Door Control Module Replacement in Doors. Did you complete the replacement? | Go to Step 38 | -- |
34 | Replace I/P dimmer switch. Refer to Instrument Panel Lamp Dimmer Switch Replacement . Did you complete the replacement? | Go to Step 38 | -- |
35 | Replace the DIM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | Go to Step 38 | -- |
36 | Replace the RIM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | Go to Step 38 | -- |
37 | Replace the inoperative courtesy lamp bulb. Did you complete the replacement? | Go to Step 38 | -- |
38 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |