GM Service Manual Online
For 1990-2009 cars only

Torque Converter Housing with Fluid Pump Removal 6L50


Object Number: 1886295  Size: LF

Callout

Component Name

Caution: The valve body assembly must be removed prior to removing the torque converter (with fluid pump) housing assembly. Failure to ensure this will cause severe damage to both fluid pump seal assemblies. Also, the load of the valve body pushing on the seals, which in turn push on the pump, may prevent proper pump installation into the case. Refer to control valve body assembly removal.

1

Turbine Shaft (O-ring) Seal

2

Bolt M8 x 1.25 x 50 (Qty: 8)

3

Torque Converter (With Fluid Pump) Housing Assembly

4

Fluid Pump Seal

Torque Converter Housing with Fluid Pump Removal 6L90


Object Number: 1696420  Size: LF

Callout

Component Name

Caution: The valve body assembly must be removed prior to removing the torque converter (with fluid pump) housing assembly. Failure to ensure this will cause severe damage to both fluid pump seal assemblies. Also, the load of the valve body pushing on the seals, which in turn push on the pump, may prevent proper pump installation into the case. Refer to control valve body assembly removal.

1

Turbine Shaft (O-ring) Seal

2

Bolt M10 x 50 (Qty: 9)

3

Torque Converter (With Fluid Pump) Housing Assembly

4

Fluid Pump Seal