Removal Procedure
Warning: Refer to Gasoline/Gasoline Vapors Warning in the Preface section.
- Remove the fuel tank pump module. Refer to
Fuel Tank Fuel Pump Module Replacement - Right Side.
Note: Do not pull on the connector wires.
- Press in the locking tab (1) and disconnect the fuel level sensor electrical connector.
- Disconnect the fuel level sensor electrical connector (1).
Note: Do not touch the resistor circuit board.
- Disengage the locking tab (1) on the fuel level sensor by pushing inward.
- Slide the fuel level sensor (1) upward to the stationary lock (2).
- Remove the fuel level sensor (1).
Installation Procedure
- Install the fuel level sensor (1).
Note: Do not push on the electrical terminals.
- Slide the fuel level sensor (1) downward until the locking tab (2) locks into place.
Note: Do not push on the electrical wires.
Note: Ensure the connector locking tab is fully seated into the flange.
- Connect the fuel level sensor electrical connector (1).
- Install the fuel tank pump module. Refer to
Fuel Tank Fuel Pump Module Replacement - Right Side.