• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Low Washer Fluid Indicator Signal | 1 | 2 | 2 | -- |
Ground | -- | 2 | -- | -- |
1. Low washer fluid message always displayed 2. Low washer fluid message never displayed |
The Check Washer Fluid message is controlled by the instrument panel cluster using an input from the washer fluid level switch. The washer fluid level signal circuit is supplied ignition voltage through a resistor then monitored within the instrument cluster. The washer fluid level switch is normally open so the instrument cluster detects ignition voltage on the washer fluid level signal circuit whenever the washer fluid level is not low. When the washer fluid reaches the point where the driver should be informed that the washer fluid is low, the washer fluid level switch closes. When the washer fluid level switch is closed the washer fluid level signal circuit voltage is pulled low, and the instrument panel displays the Check Washer Fluid message on the driver information center. In order to prevent the Check Washer Fluid message from being displayed while sloshing is occurring in the washer fluid container, the instrument cluster is programed with a 1 minute delay before changing states of the Check Washer Fluid message during an ignition cycle.
Wiper/Washer System Description and Operation
Control Module References for Scan Tool Information
⇒ | If not above the minimum level, fill the reservoir and inspect for leaks. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the IPC. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC. |
⇒ | If not the specified value, replace the washer fluid level sensor. |
⇒ | If not within the specified range, replace the washer fluid level sensor. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for IPC replacement, setup, and programming |