GM Service Manual Online
For 1990-2009 cars only
Table 1: HVAC Control Module Scan Tool Data Parameters
Table 2: HVAC Control Module Scan Tool Output Controls

HVAC Control Module Scan Tool Data Parameters

Parameter

System State

Expected Value

Description

Operating Conditions: Engine ON

A/C Compressor

--

Disengaged

The scan tool displays Engaged or Disengaged. This is the current state of the air conditioner compressor.

A/C Evap. Temperature Sensor

--

Varies

This displays °F (°C). This is the current temperature of the evaporator sensor.

A/C Head Pressure

--

Normal

The scan tool displays Out of Range or Normal. This is the current state of the air conditioner head pressure.

A/C High Side Pressure Sensor

--

Varies

This displays kPa (psi). This is the current pressure at the high side sensor.

A/C Permission

--

Varies

The scan tool displays Withheld or Granted.

A/C Request

--

No

The scan tool displays Yes or No. Yes is displayed if the air conditioner is requested.

Blower Motor Speed

--

Varies

This displays %. This is the current blower motor speed percentage.

Blower Speed

--

Off

The scan tool displays Normal or Off. This is the current state of the blower speed.

Coolant Temperature

--

Varies

This displays °F (°C). This is the current temperature of the engine coolant.

Driver Temp. Dr. Motor Command

--

Varies

This displays Counts. This is the commanded state of the driver door motor measured in counts.

Driver Temp. Dr. Position

--

Varies

This displays Counts. This is the current state of the driver door position measured in counts.

Driver Temp. Setting

--

Varies

This displays °F (°C). This is the current setting of the driver side temperature.

Inside Air Temp. Filter

--

Varies

This displays °F (°C). This is the current inside air temperature filter.

Inside Air Temp. Sensor

--

Varies

This displays °F (°C). This is the current inside air temperature sensor.

Left Sunload Sensor

--

Varies

This displays Counts. This is the current state of the left sunload sensor measured in counts.

Mode Door Position

--

Varies

This displays Counts. This is the current position of the mode door measured in counts.

Mode Dr. Motor Command

--

Varies

This displays Counts. This is the commanded state of the mode door motor measured in counts.

Outside Air Temp. Filtered

--

Varies

This displays °F (°C). This is the current filtered outside air temperature sensor.

Outside Air Temp. Raw

--

Varies

This displays °F (°C). This is the current raw outside air temperature sensor.

Passenger Temp. Setting

--

Varies

This displays °F (°C). This is the current setting of the passenger side temperature.

Psgr. Temp. Dr. Motor Command

--

Varies

This displays Counts. This is the commanded state of the passenger door motor measured in counts.

Psgr. Temp. Dr. Position

--

Varies

This displays Counts. This is the current state of the passenger door position measured in counts.

Rear Defrost State

--

Off

The scan tool displays On or Off. This is the current state of the rear defrost.

Recirculation Dr. Motor Command

--

Varies

This displays Counts. This is the commanded state of the recirculation door motor measured in counts.

Recirculation Dr. Position

--

Varies

This displays Counts. This is the current position of the recirculation door measured in counts.

Right Sunload Sensor

--

Varies

This displays Counts. This is the current state of the right sunload sensor measured in counts.

Vehicle Speed

--

0 km/h (0 mph)

The scan tool displays km/h (mph). This is the current vehicle speed.

Water Pump Relay

--

On

The scan tool displays On or Off. This is the current state of the water pump relay.

HVAC Control Module Scan Tool Output Controls

Output Control

Description

Blower Motor

This output control is used to command the blower motor.

Driver Temp. Door

This output control is used to command the driver temperature door.

Mode Door Position

This output control is used to command the mode door position.

Passenger Temp. Door

This output control is used to command the passenger temperature door.

Power Down Now

This output control is used to power down the HVAC system.

Rear Defog Request

This output control is used to command the rear defogger.

Recirculation Door

This output control is used to command the recirculation door.

Segment Check

This output control is used to command the segment check.

Water Pump Control

This output control is used to command the water pump.