Diagnostic Instructions
DTC Descriptor
DTC P0442 : Evaporative Emission (EVAP) System Small Leak Detected
Circuit Description
This diagnostic tests the evaporative emission (EVAP) system for a small leak. The diagnostic runs when the ignition is in the OFF position, and the correct conditions are met. While the engine is operating, there are sources of heat transferred into the
fuel tank from the following:
When the engine is stopped and the ignition is in the OFF position, a change in the fuel tank vapor temperature occurs. This results in a change in the pressure of the fuel tank vapor space. This change in pressure is monitored by the control module,
using the fuel tank pressure (FTP) sensor input. The EVAP diagnostic detects leaks as small as 0.51 mm (0.02 in).
FTP Sensor Signal Voltage
| Fuel Tank Pressure
|
High, Approximately 1.5 Volts or More
| Negative Pressure/Vacuum
|
Low, Approximately 1.5 Volts or Less
| Positive Pressure
|
Conditions for Running the DTC
Note: The following conditions must be met prior to the ignition OFF test.
• | DTC P0100, P0101, P0102, P0103, P0111, P0112, P0113, P0116, P0117, P0118, P0119, P0128, P0443, P0446, P0449, P0450, P0451, P0452, P0453, P0455, P0458, P0459, P0496, P0497, P0498, P0499, P0560, P0562, P0563, P0700, P2227, P2228, or P2229 is
not set. |
• | The ignition voltage is greater than 11 volts. |
• | A refueling event is not detected |
• | The fuel volatility is not excessive. |
• | The ambient air temperature (AAT) is between 2-32°C (35-90°F). |
• | The engine coolant temperature (ECT) is less than 42°C (108°F) at start-up. |
• | The ECT and the IAT are within 10°C (18°F) of each other at engine start-up. |
• | The barometric pressure (BARO) is greater than 68 kPa. |
• | The engine coolant temperature (ECT) during the previous ignition was warmer than 74°C (165°F). |
• | The fuel level is between 11-88 percent. |
• | The EVAP purge solenoid valve command is less than 26 percent-LLT only. |
• | The vehicle traveled greater than 8 km (5 mi). |
• | The engine run time is greater than 10 minutes. |
• | DTC P0442 runs once per engine off cycle when the above conditions have been met prior to engine shut down. |
Conditions for Setting the DTC
The control module detects approximately 6 vacuum/pressure changes significantly less than a calibrated amount.
Action Taken When the DTC Sets
DTC P0442 is a Type A/B DTC.
Conditions for Clearing the DTC
DTC P0442 is a Type A/B DTC.
Diagnostic Aids
• | To improve the visibility of the smoke exiting the EVAP system, observe the suspected leak area from different angles with the
J 41413-SPT
High Intensity White Light. |
• | To help locate intermittent leaks, use the
J 41413-200
Evaporative Emissions System Tester (EEST) to introduce smoke into the EVAP system. Move all EVAP components while observing smoke with the
J 41413-SPT
. Introducing smoke in 15 second intervals will allow less pressure into the EVAP system. When the system is less pressurized, the smoke will sometimes escape in a more condensed manner. |
• | Observe the Freeze Frame/Failure Records vehicle mileage since the diagnostic test last failed may help determine how often the condition occurs that caused the DTC to set. This may assist in diagnosing the condition. |
Reference Information
Schematic Reference
Evaporative Emissions Hose Routing Diagram
Connector End View Reference
Component Connector End Views
Description and Operation
Evaporative Emission Control System Description
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References for scan tool information
Special Tools
• | J 41413-200
Evaporative Emissions System Tester (EEST) |
• |
CH-48096
EVAP Service Port Access Tool |
Circuit/System Verification
- Verify the following conditions do not exist in the EVAP system:
• | Loose, incorrect, missing, or damaged fuel fill cap |
• | A damaged EVAP purge solenoid |
• | Disconnected, incorrectly routed, kinked, or damaged EVAP pipes and hoses |
• | A damaged EVAP vent valve or EVAP canister |
⇒ | If you find any of the above conditions, repair as necessary. |
Note: Refer to the
J 41413-200
operation manual for detailed instructions.
- Remove the fuel fill cap. Connect the
GE-41415-50
to the fuel tank filler neck. Connect the
J 41413-200
to the
GE-41415-50
.
- Calibrate the
J 41413-200
Flow Meter to the correct leak orifice for the vehicle.
- Command the EVAP vent solenoid closed with a scan tool.
Note: Larger volume fuel tanks and/or those with lower fuel levels may require several minutes for the floating indicator to stabilize.
- Activate the
J 41413-200
and compare the flow meter's stable floating indicator position to the red flag. The floating indicator should be below the red flag.
⇒ | If the floating indicator is above the red flag, test for a leak in the EVAP system. |
- Operate the vehicle within the Conditions for Running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
Circuit/System Testing
Note:
• | You must start with the Circuit/System Verification before proceeding with Circuit/System Testing. |
• | Ensure that the vehicle underbody temperature is similar to the ambient temperature and allow the surrounding air to stabilize before starting the diagnostic procedure. The system flow will be less with higher temperatures. |
- Connect the
GE-41415-50
to the fuel tank filler neck. Connect the
J 41413-200
to the
GE-41415-50
.
- Connect the
CH-48096
between the EVAP purge solenoid and the EVAP purge pipe.
- Turn the nitrogen/smoke valve on the control panel to SMOKE.
- Command the EVAP vent solenoid closed with a scan tool.
- Use the remote switch to introduce smoke into the EVAP system.
- Use the
J 41413-VLV
to open the EVAP service port. Once smoke is observed, remove the
J 41413-VLV
.
Note: Introduce smoke at 15 second intervals while testing the system.
- Verify that smoke is not exiting the entire EVAP system with the
J 41413-SPT
.
Note: The fuel tank may need to be lowered to improve visibility of some of the EVAP system components.
⇒ | If smoke is observed, repair the condition as necessary. |
- Remove the
J 41413-200
nitrogen supply hose from the
GE-41415-50
, and remove the
GE-41415-50
from the fuller neck.
- Install the fuel fill cap.
- Connect the
J 41413-200
nitrogen/smoke supply hose to the EVAP service port of the
CH-48096
.
- Command the EVAP vent solenoid closed with a scan tool.
- Use the remote switch to introduce smoke into the EVAP system.
Note: The fuel tank may need to be lowered to improve visibility of some of the EVAP system components.
- Verify that smoke is not exiting the entire EVAP system with the
J 41413-SPT
.
⇒ | If smoke is observed, repair the condition as necessary. |
- Verify the individual EVAP system components for a leak using the
J 41413-300
. The EVAP system components should not leak.
⇒ | If a condition is found replace the affected component. |
Repair Instructions
Repair Verification
- Turn the nitrogen/smoke valve to nitrogen.
- Command the EVAP vent valve closed with a scan tool.
- Use the remote switch to activate the
J 41413-200
.
- Use the remote switch to introduce nitrogen and fill the EVAP system until the floating indicator stabilizes.
- Verify the flow meter's stable floating indicator position is at or below the red flag.
- Remove the
CH-48096
, and connect the purge line to the EVAP purge solenoid.
- Clear the DTCs with a scan tool.