Cooling Fan After Run: The scan tool displays Not Requested/Requested.
If the engine coolant temperature is greater than 101°C (214°F) when the
engine is turned Off, the ECM will request low speed cooling fan operation, in conjunction
with the afterboil coolant pump operation. If the engine coolant temperature is
less than 101°C (214°F) after 60 seconds, the ECM will turn the cooling
fans Off. Otherwise, the ECM will turn off the cooling fans and the afterboil coolant
pump after 180 seconds on domestic vehicles, and 300 seconds on export
vehicles.
ECT: The scan tool displays -40 to +151°C
(-40 to +304°F). The Engine Coolant Temperature (ECT) sensor is
mounted in the coolant stream. The ECM applies 5 volts to the ECT sensor
circuit. The sensor is a thermistor which changes internal resistance as temperature
changes. When the sensor is cold (internal resistance high), the ECM monitors
a high signal voltage and interprets it as a cold engine. As the sensor warms and
internal resistance decreases, the voltage signal decreases and the ECM interprets
the lower voltage as a warm engine.
Engine Coolant Fan: The scan tool displays OFF, Level 1,
Level 2, or Level 3. When the scan tool displays Level 1, the
ECM is commanding the low speed fan control relay On. When the ECM commands the low
speed fan relay On, the left and right cooling fans are enabled in low speed. When
the scan tool displays Level 2, the ECM is commanding the low speed, high
speed, and S/P fan relays On. When the low speed, high speed, and S/P fan relays
are On, the left and right cooling fans are enabled in high speed. When the scan
tool displays Level 3, the ECM is commanding all fan relays On. When all fan
relays are activated, the left and right cooling fans are enabled in high speed,
and the auxiliary cooling fan, if equipped, is enabled.
Low Coolant Status: The scan tool displays OK/Low. When the
scan tool displays Low, a low voltage level has been detected on the coolant level
switch signal circuit, indicating a low coolant level condition.
Low Coolant Switch: The scan tool displays Open/Closed. When
the scan tool displays Open, the coolant level has fallen below a certain level,
causing the low coolant level switch to open, and the check coolant level display
should be activated.
Water Pump Relay: The scan tool displays On/Off. The scan tool
displays On when the HVAC control module has grounded the afterboil relay control
circuit. Grounding the afterboil relay control circuit will turn on the afterboil
relay, causing the afterboil coolant pump to turn on.