GM Service Manual Online
For 1990-2009 cars only

Circuit Description

An ignition voltage is supplied directly to the evaporative emission (EVAP) canister purge valve. The EVAP canister purge valve is pulse width modulated (PWM). The scan tool displays the amount of ON time as a percentage. The control module monitors the status of the driver. The control module controls the EVAP canister purge valve ON time by grounding the control circuit via an internal switch called a driver. If the control module detects 0 volts on the control circuit when the driver is commanded OFF, this DTC sets.

Conditions for Running the DTC

    • The engine speed is more than 400 RPM.
    • The system voltage is between 8-18 volts.

Conditions for Setting the DTC

    • The control module detects 0 volts on the EVAP purge control circuit when the driver is commanded OFF.
    • The fault is present for 50  seconds, cumulative during the drive cycle.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Test Description

The number below refers to the step number on the diagnostic table.

  1. This step tests if the concern is active. The EVAP purge valve is pulse width modulated (PWM). An audible clicking should be heard when the purge valve is commanded to 50 percent and should stop when the EVAP purge valve is commanded to 0 percent. The rate at which the valve cycles should increase as the commanded state is increased and decreased as the commanded state is decreased. Repeat the commands as necessary.

Step

Action

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check-Engine Controls?

Go to Step 2

Go to Diagnostic System Check - Engine Controls

2

  1. Turn ON the ignition, with the engine OFF.
  2. Command the EVAP canister purge valve to 50 percent and then to 0 percent with a scan tool.

Do you hear or feel a clicking from the EVAP purge valve when the valve is commanded to 50 percent?

Go to Step 3

Go to Step 4

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 4

Go to Intermittent Conditions

4

Test the control circuit of the EVAP canister purge valve for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 7

Go to Step 5

5

Test for an intermittent and for a poor connection at the control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 7

Go to Step 6

6

Replace the control module. Refer to Engine Control Module Replacement .

Did you complete the replacement?

Go to Step 7

--

7

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 2

Go to Step 8

8

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

Go to Diagnostic Trouble Code (DTC) List

System OK