Discharge Hose Replacement LA3, LY9
Tools Required
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the air deflector. Refer to
Front Air Deflector Replacement
in Body Front End.
- Remove the bolt (2) that holds the
compressor discharge hose to the compressor.
- Separate the compressor discharge hose from the compressor.
- Remove the bolt (1) from the condenser.
- Disconnect the discharge line from the condenser.
- Remove the discharge hose.
Installation Procedure
- Lubricate the O-rings. Refer to
O-Ring Replacement
.
- Install the discharge hose.
- Connect the discharge hose to compressor.
Notice: Refer to Fastener Notice in the Preface section.
- Install the discharge hose bolt (2).
Tighten
Tighten the bolt to 9.8 N·m (87 lb in).
- Install the discharge hose to the condenser.
- Install the bolt (1) to the discharge
hose.
Tighten
Tighten the bolt to 5.4 N·m (48 lb in).
- Install the air deflector. Refer to
Front Air Deflector Replacement
in Body Front End.
- Evacuate and recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using J 39400-A
.