Blower Motor Replacement LHD
Removal Procedure
- Remove the right closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages, and Console.
- Remove the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the blower motor electrical connector.
- Disconnect the blower motor processor electrical connector.
- Remove the screws (1) that retain the blower motor.
- Remove the air inlet housing bolts to gain clearence for the blower motor.
- Remove the blower motor.
Installation Procedure
- Install the blower motor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower motor screws (1).
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the air inlet housing bolts.
Tighten
Tighten the screws to 6 N·m (53 lb in).
- Connect the blower motor processor electrical connector.
- Connect the blower motor electrical connector.
- Install the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Install the right closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages, and Console.
Blower Motor Replacement RHD
Removal Procedure
- Remove the left closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in
Instrument Panel, Gages, and Console.
- Remove the IP compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the electrical
connector (1).
- Remove the blower motor
screws (1).
- Remove the blower motor.
Installation Procedure
- Install the blower motor.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the blower motor screws (1).
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the blower motor electrical connector (1).
- Install the IP compartment.
Refer to
Instrument Panel Compartment Replacement
in
Instrument Panel, Gages, and Console.
- Install the left closeout insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in
Instrument Panel, Gages, and Console.