A/C Clutch-Actual: The scan tool displays On/Off. The
HVAC control module displays On when the ECM transmits a class 2 message
that the A/C compressor clutch relay is energized.
A/C Clutch--Desired: The scan tool displays Yes/No.
The scan tool displays Yes when the HVAC control module determines that conditions
for compressor clutch engagement are present.
A/C High Side Pressure : The scan tool displays 0-3450
kPa (0-500 psi). The voltage applied to the ECM input from
the A/C refrigerant pressure sensor is converted to a pressure value.
A/C High Side Pressure : The scan tool displays 0-5
volts. The voltage applied to the ECM input for the A/C refrigerant pressure
sensor.
A/C Pressure: The scan tool displays 0-3450 kPa
(0-500 psi). The voltage applied to the ECM input from the A/C refrigerant
pressure sensor is converted to a pressure value and transmitted in a class
2 message to the HVAC control module.
A/C Relay Command: The scan tool displays On/Off. The
scan tool displays the control decision for the compressor clutch relay output
as determined by the ECM.
A/C Request Signal: The scan tool displays Yes/No. The
scan tool displays Yes when the ECM receives a class 2 message from
the HVAC control module to engage the A/C compressor clutch. The scan tool
displays No when the ECM receives a class 2 message from the HVAC
control module to disengage the A/C compressor clutch.
Commanded Blower: The scan tool displays 0-100%.
The scan tool displays the control decision for the blower motor speed as
determined by the HVAC control module. The scan tool displays 100% when
the blower motor is commanded to maximum speed. The scan tool displays
0% when the blower motor is commanded OFF.
Coolant Temperature: The scan tool displays -39 to 140°C
(-38 to 284°F) . The voltage applied to the ECM input from the engine
coolant temperature sensor is converted to a temperature value and transmitted
in a class 2 message to the HVAC control module.
Driver Temp Dr. Actual: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the driver air
temperature door position input of the HVAC control module.
Driver Temp Dr. Commanded: The scan tool displays 0-255
counts (0-5.00 Volts). The desired position of the driver air
temperature actuator as determined by the HVAC control module.
Driver Solar Sensor: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the driver sunload
input of the HVAC control module.
Driver Sunload: The scan tool displays 0-2000
w/m2. The voltage applied to the driver sunload input of the HVAC control
module converted to light intensity units.
ECT Sensor: The scan tool displays -39 to 140°C
(-38 to 284°F) . The voltage applied to the ECM input from the engine
coolant temperature sensor is converted to a temperature value.
ECT Sensor: The scan tool displays 0-5 volts.
The voltage applied to the ECM input for the engine coolant temperature sensor.
Evaporator Temp: The scan tool displays -39 to 140°C
(-38 to 284°F). The voltage applied to the HVAC control module input
from the evaporator temperature sensor is converted to a temperature value.
Evaporator Temp: The scan tool displays 0-255
counts (0-5 Volts). The voltage applied to the HVAC control module
input for the evaporator temperature sensor.
Htr./Def./A/C Dr. Actual: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the mode door
position input of the HVAC control module.
Htr./Def./A/C Dr. Commanded: The scan tool displays
0-255 counts (0-5.00 Volts). The desired position of the
mode actuator as determined by the HVAC control module.
Inside Air Temp.: The scan tool displays -40 to
215°C (-40 to 419°F). The voltage applied to the HVAC control module
input for the inside air temperature sensor is converted to a temperature
value.
Inside Air Temp.: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the HVAC control
module input for the inside air temperature sensor.
Low Coolant Status: The scan tool displays OK/Low. The
filtered state of the low coolant switch.
Low Coolant Switch: The scan tool displays Open/Closed.
The actual state of the low coolant switch.
Outside Air Temp. : The scan tool displays -40
to 215°C (-40 to 419°F). The current value of the ambient air temperature
display on the HVAC control module.
Outside Air Temp. : The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the HVAC control
module input for the outside air temperature sensor.
Passenger Solar Sensor: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the passenger
sunload input of the HVAC control module.
Passenger Sunload: The scan tool displays 0-2000
w/m2. The voltage applied to the driver sunload input of the HVAC control
module converted to light intensity units.
Passenger Temp Dr. Actual: The scan tool displays 0-255
counts (0-5.00 Volts). The voltage applied to the passenger
air temperature door position input of the HVAC control module.
Passenger Temp Dr. Commanded: The scan tool displays
0-255 counts (0-5.00 Volts). The desired position of the
passenger air temperature actuator as determined by the HVAC control module.
Pressure Sensor: The scan tool displays OK/Failed. The
state of the A/C refrigerant pressure sensor and circuitry.