Step
| Action
| Value(s)
| Yes
| No
|
1
| Was the Power Sun Roof System Check performed?
| --
|
Go to Step 2
| Go to
Power Sunroof System Check
|
2
|
- Install the scan tool.
- The scan tool can be used to operate the sun roof actuator.
- Attempt to operate the sun roof actuator with the scan tool.
Does the sun roof actuator operate when using the scan tool?
| --
|
Go to Step 9
|
Go
to Step 3
|
3
|
- Disconnect the sun roof actuator connector.
- Use the DMM to measure the voltage between terminal 1 of the sun
roof actuator connector and a known good ground.
Is the measured voltage within the specified value?
| B+
|
Go
to Step 5
|
Go to Step 4
|
4
|
- Inspect fuse #25. If it is open, replace it.
- Locate an open or a high resistance in circuits A700 and/or A701.
- Repair the open or the high resistance in circuits A700 and/or
A701.
Is the repair complete?
| --
|
Go to Step 10
| --
|
5
|
- Turn the ignition switch to the ON position.
- Use the DMM to measure the voltage between terminal 5 of the sun
roof actuator connector and a known good ground.
Is the measured voltage within the specified value?
| B+
|
Go
to Step 7
|
Go to Step 6
|
6
|
- Locate an open or a high resistance in circuit X700.
- Repair the open or the high resistance in circuit X700.
Is the repair complete?
| --
|
Go to Step 10
| --
|
7
| Use the DMM to measure the resistance between terminal 2 of the sun
roof actuator connector and a known good ground.
Is the measured resistance within the specified value?
| Less than 5 ohms
|
Go to Step 9
|
Go to Step 8
|
8
|
- Locate an open or a high resistance in circuit F700.
- Repair the open or the high resistance in circuit F700.
Is the repair complete?
| --
|
Go to Step 10
| --
|
9
| Replace the sun roof actuator. Refer to
Sunroof Actuator Replacement
in Roof.
Is the replacement complete?
| --
|
Go to Step 10
| --
|
10
|
- Connect all connectors and components that were disconnected.
- Verify that the sun roof actuator operates properly.
Does the sun roof actuator operate?
| --
| System OK
|
Go
to Step 1
|