Removal Procedure
Important:
• | Always use replacement cables that are of the same type, diameter and length of the cables that you are replacing. |
• | Always route the replacement cable the same way as the original cable. |
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Disconnect the body harness electrical connector from the negative battery cable electrical connector.
- Disconnect the body harness electrical connector from the battery current sensor.
- Remove the negative battery cable ground bolt.
- Remove the negative battery cable.
Installation Procedure
Important: When installing the negative battery cable, ensure that the cable eyelet is installed with the flat side down. Keep the crimped side facing upward.
- Place the negative battery cable eyelet over the hole in the floor pan.
Notice: Refer to Fastener Notice in the Preface section.
- Install the negative battery cable ground bolt.
Tighten
Tighten the bolt to 36 N·m (27 lb ft).
- Connect the body harness electrical connector to the battery current sensor.
- Connect the body harness electrical connector to the negative battery cable electrical connector.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.