Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Battery Positive Voltage | 1 | 1 | -- | -- |
Ignition 3 Voltage | 1 | 1 | -- | -- |
Driver Seat Blower Supply Voltage | B103D | B272E | B272E | -- |
Driver Seat Back Blower Supply Voltage | B103D | B272C, B727E, B2730 | B272E | -- |
Driver Seat Cushion Blower Supply Voltage | B103D | B272C, B2729 | B272E | -- |
Driver Heated Seat Back Only Mode Switch Signal | 5 | 5 | 5 | -- |
Driver Heated Seat Cool Switch Signal | 4 | 4 | 4 | -- |
Driver Seat Back Cushion Switch Signal | 3 | 3 | 3 | -- |
Driver Seat Back Temperature Sensor Signal | B272C, B2730 | B1AA1, B272C | B1AA1, B272C | -- |
Driver Seat Cushion Temperature Sensor Signal | B272C, B2729 | B1AA0, B272C | B1AA0, B272C | -- |
Left Heated/Cooled Seat Mode Signal | 2 | 2 | 2 | -- |
Driver Seat Back Heated/Cool Ventilation Module Cool Control | B103A | B272C, 4, 5 | -- | -- |
Driver Seat Back Heated/Cool Ventilation Module Heat Control | B103A, 4 | B272C, 4, 5 | -- | -- |
Driver Seat Cushion Heated/Cool Ventilation Module Cool Control | B103A | B272C, 4 | -- | -- |
Driver Seat Cushion Heated/Cool Ventilation Module Heat Control | B103A, 4 | B272C | 4 | -- |
Driver Seat Back Blower Speed Control | B19A8 | B272C, B272E, B2730 | B19A4 | -- |
Driver Seat Cushion Blower Speed Control | B19A7 | B272C, B2729 | B19A3 | -- |
Low Reference - Driver Heated Seat Switch | -- | 2 | -- | -- |
Low Reference - Driver Seat Back Blower | -- | B272C, B272E, B2730 | -- | -- |
Low Reference - Driver Seat Back and Cushion Blower | -- | B272E | -- | -- |
Low Reference - Driver Seat Cushion Blower | -- | B272C, B2729 | -- | -- |
Low Reference - Driver Seat Back Temperature Sensor | -- | B1AA1, B272C | -- | -- |
Low Reference - Driver Seat Cushion Temperature Sensor | -- | B1AA0, B272C | -- | -- |
Ground - Climate Control Seat Module | -- | 1 | -- | -- |
1. Driver and passenger heated/cooled seats are inoperative, the CCSM does not communicate with the scan tool. 2. Driver heated and cooled seat inoperative 3. Seat heat mode is inoperative 4. Seat cool mode is inoperative 5. Heated/cooled seat back only mode inoperative |
The heat and cool seat functions for the driver and passenger seats are controlled by the climate control seat module (CCSM) that is located under the passenger seat cushion. When a driver or passenger heat or cool seat switch is pressed, a low reference signal is applied through the switch signal circuit to the door control module. In response to the switch input, the door module sends a GMLAN message to the memory seat module (MSM) indicating the heat/cool seat request. The MSM then sends a pulse width modulation (PWM) signal through the heated/cooled seat mode signal circuit to the CCSM. The CCSM then applies battery positive voltage to the seat cushion and seat back thermal electronic devices (TEDs) and a pre-determined voltage to the blower motors. To determine seat temperature, the CCSM supplies a 5-volt signal and a low reference to the temperature sensors that are attached to each TED. The temperature sensors are variable resistors. Their resistance changes as the temperature of the seat changes. Then based on the seat temperature, the CCSM controls the voltage level that it applies to the TEDs and blower motors.
Ignition ON and the driver heat or cool seat is commanded On.
The CCSM detects a short to ground on one of the ventilation modules heat or cool control circuits.
The CCSM will disable the heat or cool seat function for the current ignition cycle.
The current DTC clears when the malfunction is no longer present and the power mode changes to OFF then back to ACC or RUN.
• | In order to perform valid tests when diagnosing the climate control seat system, the ignition must be cycled OFF then ON between each test in order to reset the CCSM. |
• | A short to battery voltage on a temperature sensor signal circuit will open the sensor. |
Power Seat Connector End Views
Ignition ON, press the driver heated seat cushion/back heat mode switch. The heated seat switch temperature indicators should illuminate and the seat should operate in the high heat mode. Press the heated seat back only mode switch, the heated seat switch temperature indicators should illuminate and the seat should operate in the back only heat mode. Press the heated seat cool mode switch, the heated seat switch temperature indicators should illuminate and the seat should operate in the cool mode.
• | Seat cushion heat control circuit terminal G |
• | Seat cushion cool control circuit terminal H |
• | Seat back heat control circuit terminal J |
• | Seat back cool control circuit terminal K |
⇒ | If not the specified value, test the appropriate control circuit for a short to ground. |
Important: The test leads must be connected in the correct polarity, otherwise lower out of range values will appear. Use the Positive Lead for the COOL control circuit and the Negative Lead for the HEAT control circuit. If the
resistance is measured with the seat still warm or cool, the resistance values will vary even if the system was powered up for just a few seconds. The TED must be allowed to stabilize to room temperature prior to a measurement. The following conditions will
change the resistance to out of range values:
• The test leads are incorrectly connected • Air blowing across the TED • Measuring the resistance at other than room temperature of 70°F • Holding the TED portion of the heated and cool ventilation module in your hand
⇒ | If not within the specified range, replace the seat cushion ventilation heat and cool module. |
⇒ | If not within the specified range, replace the seat back ventilation heat and cool module. |
Important: If the resistance is measured with the seat still warm or cool, the resistance values will vary. At 68°F (20°C), the nominal resistance value is 1200 ohms ±5 percent. For hotter or colder ambient temperatures, refer to the Temperature vs Resistance table below. The delta resistance values between the seat cushion and seat back temperature sensors should not be greater than 2000 ohms.
⇒ | If not within the specified range, replace the ventilation heat and cool module. |
Important: The test leads must be connected in the correct polarity, otherwise lower out of range values will appear. Use the Positive Lead for the COOL control circuit and the Negative Lead for the HEAT control circuit. If the
resistance is measured with the seat still warm or cool, the resistance values will vary even if the system was powered up for just a few seconds. The TED must be allowed to stabilize to room temperature prior to a measurement. The following conditions will
change the resistance to out of range values:
• The test leads are incorrectly connected • Air blowing across the TED • Measuring the resistance at other than room temperature of 70°F • Holding the TED portion of the heated and cool ventilation module in your hand
⇒ | If not within the specified range, replace the ventilation heat and cool module. |
Important: The test leads must be connected in the correct polarity, otherwise higher out of range values will appear. Use the Positive Lead for the supply voltage circuit and the Negative Lead for the ground circuit.
⇒ | If not within the specified range, replace the ventilation heat and cool module. |
Important: The test leads need to be connected in the correct polarity, otherwise higher out of range values will appear. Use the Positive Lead for the speed control circuit and the Negative Lead for the ground circuit.
⇒ | If not within the specified range, replace the ventilation heat and cool module. |
°C | °F | OHMS |
---|---|---|
Temperature vs Resistance Values (Approximate) | ||
60° | 140° | 319.9 |
50° | 122° | 433.1 |
40° | 104° | 596.6 |
30° | 86° | 837.5 |
20° | 68° | 1200 |
10° | 50° | 1757 |
0° | 32° | 2633 |
-10° | 14° | 4047 |
-20° | -4° | 6401 |
-30° | -22° | 10,450 |
-40° | -40° | 17,670 |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for CCSM replacement, setup, and programming |