• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Steering Column Tilt Up Switch Signal | 1 | 1 | B2870 | -- |
Steering Column Tilt Down Switch Signal | 1 | 1 | B2875 | -- |
Steering Column Telescope Reverse Switch Signal | 2 | 2 | B2855 | -- |
Steering Column Telescope Forward Switch Signal | 2 | 2 | B2850 | -- |
1. Tilt Malfunction 2. Telescope Malfunction |
The memory seat module (MSM) receives voltage inputs from the tilt/telescope switch based on the position of the switch. The MSM then supplies battery voltage and a ground to the tilt or telescope motor control circuits depending on which direction of movement is requested.
The ignition ON.
The MSM detects a telescope rearward switch input for more than 30 consecutive seconds after rearward movement of the motor has stopped.
• | The telescope motor will be deactivated. |
• | Memory recall functions will be disabled. |
• | A current DTC will clear when the failed switch input is no longer active. |
• | A history DTC will clear after 100 ignition cycles. |
An intermittently stuck telescope switch may cause this DTC to set.
Tilt/Telescoping Steering Column Schematics
Steering Wheel and Column Connector End Views
Steering Wheel and Column Description and Operation
Ignition ON, view the scan tool Telescope Rearward Switch parameter while cycling the tilt/telescope switch between the neutral and TELESCOPE OUT position. The parameter should change between Active and Inactive.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 2 for a short to voltage. If the circuit tests normal, replace the MSM. |
⇒ | If not the specified value, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the MSM. |
• | B+ terminal 4 and signal terminal 5 |
• | B+ terminal 4 and signal terminal 1 |
• | B+ terminal 4 and signal terminal 2 |
• | B+ terminal 4 and signal terminal 3 |
⇒ | If less than the specified range, replace the tilt/telescope switch. |
⇒ | If greater than the specified range, replace the tilt/telescope switch. |
⇒ | If greater than the specified range, replace the tilt/telescope switch. |
⇒ | If greater than the specified range, replace the tilt/telescope switch. |
⇒ | If greater than the specified range, replace the tilt/telescope switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for MSM replacement, setup, and programming |