GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC B103A: Driver Thermal Electronic Device Control Current Above Threshold

DTC B1111: Driver Thermal Electronic Device Circuit

Diagnostic Fault Information

Circuit

Short to Ground

Open/High Resistance

Short to Voltage

Signal Performance

Battery Positive Voltage

1

1

--

--

Ignition 3 Voltage

1

1

--

--

Driver Seat Blower Supply Voltage

B103D

B272E

B272E

--

Driver Seat Back Blower Supply Voltage

B103D

B272C, B727E, B2730

B272E

--

Driver Seat Cushion Blower Supply Voltage

B103D

B272C, B2729

B272E

--

Driver Heated Seat Back Only Mode Switch Signal

5

5

5

--

Driver Heated Seat Cool Switch Signal

4

4

4

--

Driver Seat Back Cushion Switch Signal

3

3

3

--

Driver Seat Back Temperature Sensor Signal

B272C, B2730

B1AA1, B272C

B1AA1, B272C

--

Driver Seat Cushion Temperature Sensor Signal

B272C, B2729

B1AA0, B272C

B1AA0, B272C

--

Left Heated/Cooled Seat Mode Signal

2

2

2

--

Driver Seat Back Heated/Cool Ventilation Module Cool Control

B103A

B272C, 4, 5

--

--

Driver Seat Back Heated/Cool Ventilation Module Heat Control

B103A, 4

B272C, 4, 5

--

--

Driver Seat Cushion Heated/Cool Ventilation Module Cool Control

B103A

B272C, 4

--

--

Driver Seat Cushion Heated/Cool Ventilation Module Heat Control

B103A, 4

B272C

4

--

Driver Seat Back Blower Speed Control

B19A8

B272C, B272E, B2730

B19A4

--

Driver Seat Cushion Blower Speed Control

B19A7

B272C, B2729

B19A3

--

Low Reference - Driver Heated Seat Switch

--

2

--

--

Low Reference - Driver Seat Back Blower

--

B272C, B272E, B2730

--

--

Low Reference - Driver Seat Back and Cushion Blower

--

B272E

--

--

Low Reference - Driver Seat Cushion Blower

--

B272C, B2729

--

--

Low Reference - Driver Seat Back Temperature Sensor

--

B1AA1, B272C

--

--

Low Reference - Driver Seat Cushion Temperature Sensor

--

B1AA0, B272C

--

--

Ground - Climate Control Seat Module

--

1

--

--

1. Driver and passenger heated/cooled seats are inoperative, the CCSM does not communicate with the scan tool.

2. Driver heated and cooled seat inoperative

3. Seat heat mode is inoperative

4. Seat cool mode is inoperative

5. Heated/cooled seat inoperative - Back Only Mode

Circuit/System Description

The heat and cool seat functions for the driver and passenger seats are controlled by the climate control seat module (CCSM) that is located under the passenger seat cushion. When a driver or passenger heat or cool seat switch is pressed, a low reference signal is applied through the switch signal circuit to the door control module. In response to the switch input, the door module sends a GMLAN message to the memory seat module (MSM) indicating the heat/cool seat request. The MSM then sends a pulse width modulation (PWM) signal through the heated/cooled seat mode signal circuit to the CCSM. The CCSM then applies battery positive voltage to the seat cushion and seat back thermal electronic devices (TEDs) and a pre-determined voltage to the blower motors. To determine seat temperature, the CCSM supplies a 5-volt signal and a low reference to the temperature sensors that are attached to each TED. The temperature sensors are variable resistors. Their resistance changes as the temperature of the seat changes. Then based on the seat temperature, the CCSM controls the voltage level that it applies to the TEDs and blower motors.

Conditions for Running the DTC

Ignition ON and the driver heat or cool seat is commanded On.

Conditions for Setting the DTC

The CCSM detects a short to ground on one of the ventilation modules heat or cool control circuits.

Action Taken When the DTC Sets

The CCSM will disable the heat or cool seat function for the current ignition cycle.

Conditions for Clearing the DTC

The current DTC clears when the malfunction is no longer present and the power mode changes to OFF then back to ACC or RUN.

Diagnostic Aids

    • In order to perform valid tests when diagnosing the climate control seat system, the ignition must be cycled OFF then ON between each test in order to reset the CCSM.
    • A short to battery voltage on a temperature sensor signal circuit will open the sensor.

Reference Information

Schematic Reference

Heated/Cooled Seat Schematics

Connector End View Reference

Heated/Cooled Seat Connector End Views

Description and Operation

Heated/Cooled Seats Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

    •  Scan Tool Output Controls
    •  Scan Tool Data List
    •  Scan Tool Data Definitions

Circuit System Verification

Ignition ON, press the driver heated seat cushion/back heat mode switch. The heated seat switch temperature indicators should illuminate and the seat should operate in the high heat mode. Press the heated seat back only mode switch, the heated seat switch temperature indicators should illuminate and the seat should operate in the back only heat mode. Press the heated seat cool mode switch, the heated seat switch temperature indicators should illuminate and the seat should operate in the cool mode.

Circuit/System Testing

  1. Ignition OFF, disconnect the C1 harness connector at the CCSM.
  2. Test for infinite resistance between the control circuits listed below and ground:
  3. • Seat cushion heat control circuit terminal G
    • Seat cushion cool control circuit terminal H
    • Seat back heat control circuit terminal J
    • Seat back cool control circuit terminal K
    If not the specified value, test the appropriate control circuit for a short to ground.
  4. Disconnect the harness connectors at the seat cushion and seat back ventilation heat and cool modules.
  5. Important: The test leads must be connected in the correct polarity, otherwise lower out of range values will appear. Use the Positive Lead for the COOL control circuit and the Negative Lead for the HEAT control circuit. If the resistance is measured with the seat still warm or cool, the resistance values will vary even if the system was powered up for just a few seconds. The TED must be allowed to stabilize to room temperature prior to a measurement. The following conditions will change the resistance to out of range values:

       • The test leads are incorrectly connected
       • Air blowing across the TED
       • Measuring the resistance at other than room temperature of 70°F
       • Holding the TED portion of the heated and cool ventilation module in your hand
    In warmer or cooler climates where room temperature conditions of 70°F (21°C) may be unattainable, resistance values may read above the specified range. Use a heat gun or a blower to warm or cool the TED while measuring the resistance. The resistance values should slowly lower toward the specified range.

  6. From the seat cushion ventilation module side of the harness connector, test for 0.9-10 Ω between control circuit terminal 1 and control circuit terminal 3.
  7. If not within the specified range, test or replace the seat cushion ventilation heat and cool module.
  8. From the seat back ventilation module side of the harness connector, test for 0.9-10 Ω between control circuit terminal 1 and l control circuit terminal 3.
  9. If not within the specified range, test or replace the seat back ventilation heat and cool module.
  10. If all circuits test normal, replace the CCSM.

Component Testing

Ventilation Heat and Cool Module

  1. Ignition OFF, disconnect the harness connector at the appropriate seat cushion or seat back ventilation heat and cool module.
  2. Important: If the resistance is measured with the seat still warm or cool, the resistance values will vary. At 68°F (20°C), the nominal resistance value is 1200 Ω ±5 percent. For warmer or cooler ambient temperatures, refer to the Temperature vs Resistance table below. The delta resistance values between the seat cushion and seat back temperature sensors should not be greater than 2000 Ω.

  3. Test for 300 Ω-18 kΩ between the signal circuit terminal 5 and the low reference circuit terminal 8.
  4. If not within the specified range, replace the ventilation heat and cool module.

    Important: The test leads must be connected in the correct polarity, otherwise lower out of range values will appear. Use the Positive Lead for the COOL control circuit and the Negative Lead for the HEAT control circuit. If the resistance is measured with the seat still warm or cool, the resistance values will vary even if the system was powered up for just a few seconds. The TED must be allowed to stabilize to room temperature prior to a measurement. The following conditions will change the resistance to out of range values:

       • The test leads are incorrectly connected.
       • Air blowing across the TED
       • Measuring the resistance at other than room temperature of 70°F
       • Holding the TED portion of the heated and cool ventilation module in your hand
    In warmer or cooler climates where room temperature conditions of 70°F (21°C) may be unattainable, resistance values may read above the specified range. Use a heat gun or a blower to warm or cool the TED while measuring the resistance. The resistance values should slowly lower toward the specified range.

  5. Test for 0.9-10 Ω between control circuit terminal 1 and control circuit terminal 3.
  6. If the resistance is not within the specified range, replace the ventilation heat and cool module.

    Important: The test leads must be connected in the correct polarity, otherwise higher out of range values will appear. Use the Positive Lead for the supply voltage circuit and the Negative Lead for the ground circuit.

  7. Test for 6 k-9 kΩ between control circuit terminal 2 and the low reference circuit terminal 4.
  8. If the resistance is not within the specified range, replace the ventilation heat and cool module.

    Important: The test leads need to be connected in the correct polarity, otherwise higher out of range values will appear. Use the Positive Lead for the speed control circuit and the Negative Lead for the ground circuit.

  9. Test for 290 k-420 kΩ between control circuit terminal 7 and the low reference circuit terminal 4.
  10. If the resistance is not within the specified range, replace the ventilation heat and cool module.

Temperature vs Resistance

°C

°F

Ω

Temperature vs Resistance Values (Approximate)

60°

140°

319.9

50°

122°

433.1

40°

104°

596.6

30°

86°

837.5

20°

68°

1200

10°

50°

1757

32°

2633

-10°

14°

4047

-20°

-4°

6401

-30°

-22°

10,450

-40°

-40°

17,670

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Driver or Passenger Seat Back Ventilation Heating and Cooling Blower Replacement
    •  Driver or Passenger Seat Cushion Ventilation Heating and Cooling Blower Replacement
    •  Control Module References for CCSM replacement, setup, and programming