• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Low Beam Headlamp Supply Voltage | 1 | 1 | 3 | -- |
High Beam Headlamp Supply Voltage | 2 | 2 | 4 | -- |
Headlamp Low Beam Relay Control | 1 | 1 | B2575 00 | -- |
Headlamp High Beam Relay Control | 2 | 2 | B2580 00 | -- |
Headlamp Switch Headlamps Off Signal | B257A 00 | 6 | 6* | -- |
Headlamp Switch Headlamps On Signal | B257A 00 | 1 | 1* | -- |
Flash to Pass Switch Signal | 4 | 5 | 5* | -- |
Headlamp Dimmer Switch High Beam Signal | 4 | 2 | 2* | -- |
Low Beam Headlamp Ground | -- | 1 | 1 | -- |
High Beam Headlamp Ground | -- | 2 | 2 | -- |
Headlamp Switch Ground | -- | 1, 2 | 1, 2 | -- |
Turn Signal/Multifunction Switch Ground | -- | 2, 5 | 2, 5 | -- |
* Internal damage to the switch may occur if shorted to B+
|
The vehicle headlamps are controlled by the body control module (BCM) based on inputs from the headlamp switch and the turn signal/multifunction switch. The headlamp switch has four positions: Off, Auto, Park, and Headlamps. The default headlamp switch position is Auto, in which the BCM uses the ambient light sensor to determine when headlamps are needed. The Off portion of the headlamp switch is a momentary switch which overrides the automatic headlamps and will turn off the vehicle headlamps. When in the Off position, the headlamp switch grounds the headlamp switch headlamps off signal circuit, prompting the BCM to turn off all exterior lamps. The Park position of the headlamp switch will only illuminate the vehicle parking lamps. The Headlamp position of the headlamp switch will illuminate both the parking lamps, as well has the headlamps. With the headlamp switch in the Headlamp position, the headlamp switch headlamps on signal circuit is grounded, prompting the BCM to turn on the headlamps, regardless of other factors such as ambient light.
The headlamp high beams are controlled through the flash to pass switch and the headlamp dimmer switch, both located in the turn signal/multifunction switch. The flash to pass switch is a momentary type switch, designed to illuminate the high beams as long as the switch is held. With the switch closed, the flash to pass switch signal circuit is grounded, prompting the BCM to turn on the high beam lamps. The headlamp dimmer switch allows the operator to select between full time high or low beam operation. Unlike the flash to pass switch, it is not a momentary switch. When the headlamp dimmer switch is in the high beam position, the headlamp dimmer switch high beam signal circuit is grounded. This prompts the BCM to turn on the high beam lamps.
The BCM controls the headlamps based on the inputs explained above. When a low beam request is received, the BCM grounds the headlamp low beam relay control circuit. This energizes the coil in the LO BEAM PCB Relay, causing the relay switch to close. This then applies B+ through the LT LO BEAM and RT LO BEAM fuses, the headlamp supply voltage circuits to the headlamp ballasts, illuminating the headlamps. When a high beam request is received, the BCM grounds the headlamp high beam relay control circuit. This energizes the coil in the HIGH BEAM PCB Relay, causing the relay switch to close. Battery voltage is then applied through both HI BEAM fuses and the high beam headlamp supply voltage circuits to the headlamp high beam solenoids. The solenoids then open the low beam shields to fully expose the headlamp bulbs for high beam operation.
Headlights/Daytime Running Lights (DRL) Schematics
Lighting Systems Connector End Views
Exterior Lighting Systems Description and Operation
⇒ | If the parameter does not cycle between the specified values, refer to Headlamp Switch Circuit Test. |
⇒ | If the parameter does not cycle between the specified values, refer to Headlamp Switch Test. |
⇒ | If the parameter does not cycle between the specified values, refer to Turn Signal/Multifunction Switch Test. |
⇒ | If the parameter does not cycle between the specified values, refer to Turn Signal/Multifunction Switch Test. |
⇒ | If the test lamp is always OFF, or remains always ON, refer to Low Beam PCB Relay Circuit Test. |
⇒ | If the test lamp turns ON and OFF, refer to Headlamps Circuit Test |
⇒ | If the test lamp is always OFF, or remains always ON, refer to High Beam PCB Relay Circuit Test. |
⇒ | If the test lamp turns ON and OFF, refer to High Beam Circuit Test |
⇒ | If the indicator is always OFF or remains always ON, replace the IPC. |
Caution: The high intensity discharge system produces high voltage and current.
To reduce the risk of severe shocks and burns:
• Never open the high intensity discharge system ballast or the
arc tube assembly starter. • Never probe between the high intensity discharge system ballast
output connector and the arc tube assembly.
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit terminal 3 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit terminal E for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the supply voltage circuit for a short to voltage. If the circuit tests normal, replace the underhood fuse block. |
⇒ | If the test lamp is always OFF, test the supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the underhood fuse block. |
⇒ | If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the supply voltage circuit for a short to voltage. If the circuit tests normal, replace the underhood fuse block. |
⇒ | If the test lamp is always OFF, test the supply voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the underhood fuse block. |
⇒ | If not the specified value, replace the headlamp switch. |
⇒ | If not the specified value, replace the headlamp switch. |
⇒ | If not the specified value, replace the headlamp switch. |
⇒ | If not the specified value, replace the headlamp switch. |
⇒ | If not the specified value, replace the turn signal/multifunction switch. |
⇒ | If not the specified value, replace the turn signal/multifunction switch. |
⇒ | If not the specified value, replace the turn signal/multifunction switch. |
⇒ | If not the specified value, replace the turn signal/multifunction switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup and programming. |