• | If the control A circuit of the recirculation actuator is shorted to ground, the following conditions will occur. |
- | The recirculation actuator will operate properly when recirculation is requested. |
- | The recirculation actuator will continually modulate between the outside air and recirculation positions when outside air is requested. |
• | If the control B circuit of the recirculation actuator is shorted to ground, the following conditions will occur. |
- | The recirculation actuator will operate properly when outside air is requested. |
- | The recirculation actuator will continually modulate between the outside air and recirculation positions when recirculation is requested. |
• | Inspect the recirculation door and the recirculation actuator for the following conditions: |
- | A misaligned recirculation actuator--Refer to Recirculation Actuator Replacement. |
- |
- | Broken or binding linkages |
- | A broken or binding recirculation door |
- | An obstruction that prevents the recirculation door from operating within its full range of motion |
- | Missing seals to the recirculation door |
- | Misaligned seals to the recirculation door |
Step | Action | Yes | No | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||||||||
2 |
Do you hear an audible difference in the airflow when the recirculation switch is placed in the recirculation position? | Go to Diagnostic Aids | Go to Step 3 | ||||||||||||||
3 |
Does the drive shaft of the recirculation actuator rotate? | Go to Diagnostic Aids | Go to Step 4 | ||||||||||||||
4 |
Does the drive shaft of the recirculation actuator rotate? | Go to Step 12 | Go to Step 5 | ||||||||||||||
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 13 | ||||||||||||||
6 |
Does the test lamp illuminate with either command? | Go to Step 7 | Go to Step 8 | ||||||||||||||
7 |
Does the test lamp illuminate with either command? | Go to Step 10 | Go to Step 9 | ||||||||||||||
8 | Test the control A circuit of the recirculation actuator for the following:
Refer to Circuit Testing and Wiring Repairs. Did you find and correct the condition? | Go to Step 16 | Go to Step 12 | ||||||||||||||
9 | Test the control B circuit of the recirculation actuator for the following:
Refer to Circuit Testing and Wiring Repairs. Did you find and correct the condition? | Go to Step 16 | Go to Step 12 | ||||||||||||||
10 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | Go to Step 16 | Go to Step 11 | ||||||||||||||
11 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 | ||||||||||||||
12 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 | ||||||||||||||
13 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs. Did you complete the repair? | Go to Step 16 | -- | ||||||||||||||
14 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 16 | -- | ||||||||||||||
15 | Replace the HVAC control module. Refer to Control Module References for replacement, setup and programming. Did you complete the replacement? | Go to Step 16 | -- | ||||||||||||||
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |