Special Tools
• | J 39686 Input End Play Check Tool |
• | J 8001 Dial Indicator Set |
For equivalent regional tools, refer to
Special Tools.
- Install the
J 39686 input end play check tool
into the case barrel and install the post.
- Locate the J tab on the input shaft (604). The arrow on the tab should have a 90 degree orientation.
- The washer must rest flat on the case cover seal. Rotate the threaded shaft clockwise until tight. Leave enough space for the collar.
- Insert the collar. Install the
J 8001 dial indicator set
.
- Push down on the handle and check the end play. The end play specification is
0.10-0.85 mm (0.004-0.033 in).
If the measurement is out of the specification range,
determine the appropriate selective thrust washer (522) for installation upon reassemble.
- Remove the dial indicator and the post.