Tools Required
GM P/N 12303040
- Use a voltmeter in order to check the voltage across the battery
terminals. If the green dot is visible, the voltage should be 12 volts or
above. If not, replace the battery. Refer to
Battery Replacement
- Install battery side terminal adapters.
- Connect a voltmeter and a battery lead tester across the battery
terminals.
- Apply a 300 ampere load for 15 seconds in order to remove
the surface charge from the battery. Remove the load.
- Wait 15 seconds in order to let the battery recover, then apply
the specified load from the specifications. Read the voltage after 15 seconds,
then turn off the load.
Important: The battery temperature must be estimated by the feel and by the temperature
the battery has been exposed to for the preceding few hours.
- When the voltage does not drop below the minimum voltage, the battery
is good and should be returned to service. If the voltage is less than the
minimum, replace the battery. Refer to Battery Voltage vs Temperature