J 39400 Halogen Leak Detector
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the condenser mounting bolt to 13 N·m (10 lb ft).
Important: Inspect the sealing washers for damage.
Any sealing washers that show any signs of damage need to be replaced. Sealing washers do not require lubrication.Tighten
Tighten the evaporator hose fastener (1) to 20 N·m (15 lb ft).
Tighten
Tighten the discharge hose to 20 N·m (15 lb ft).