The inflatable restraint side impact module - RR (supplemental deployment loop #2) consists of an inflatable restraint side impact module - RR, the side impact module - RR high and side impact module - RR low circuits. A shorting bar is used in the side impact module - RR connector which will short together the side impact module - RR high and low circuits when the connector is disconnected, this will help to prevent unwanted deployment of the side impact module during servicing. During a frontal crash of sufficient force the inflatable restraint sensing and diagnostic module (SDM) will allow current to flow through the deployment loop in order to deploy the side impact module. The SDM performs continuous diagnostic tests on the deployment loops to check for proper circuit continuity and for shorts to ground or voltage. If a malfunction is detected, a DTC will be stored in non-volatile memory.
Ignition 1 Voltage is within the normal operating voltage range.
The DTC will set if one of the following conditions occurs:
• | Side impact module - RR high and/or low is short to ground or a short to voltage for 500 milliseconds. |
• | Side impact module - RR high terminal is less than 2.4 volts and side impact module - RR deployment loop resistance is less than 6 ohms for 500 milliseconds. |
The SDM commands the AIR BAG warning indicator ON via Class 2 serial data.
• | The condition responsible for setting the DTC no longer exists and the scan tool Clear DTCs function is used. |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred. |
The following are possible causes of the malfunction:
• | A short to ground or a short to voltage in the side impact module - RR circuits. |
• | A malfunctioning inflatable restraint side impact module - RR. |
• | An internal SDM malfunction. |
Thoroughly inspect the wiring and the connectors. An incomplete inspection of the wiring and the connectors may result in a misdiagnosis, causing a part replacement with the reappearance of the malfunction. If an intermittent malfunction exists, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The number(s) below refer to the step number(s) on the diagnostic table.
Test to see if there is a malfunctioning side impact module - RR.
Test for a short to ground or a short to voltage in the side impact module - RR high and low circuits.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: SIR Schematics | |||
1 | Did you perform A Diagnostic System Check - SIR? | Go to Step 2 | |
2 |
Does connector exhibits any signs of damage or corrosion? | Go to Step 3 | Go to Step 4 |
3 |
Did you complete the repair? | Go to Step 9 | -- |
Does the scan tool indicate that this DTC 0088 is current? | Go to Step 5 | Go to Step 7 | |
5 |
Did you find and correct the condition? | Go to Step 9 | Go to Step 6 |
Test the side impact module - RR high and side impact module - RR low circuits for a short to ground or a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 9 | Go to Step 8 | |
7 |
Did you complete the replacement? | Go to Step 9 | -- |
8 |
Did you complete the replacement? | Go to Step 9 | -- |
9 |
Does the DTC reset? | Go to Step 2 | System OK |