When you turn ON the ignition switch, the control module enables the fuel pump relay which powers the fuel pump ON. The fuel pump remains ON as long as the engine is cranking or running and the control module receives ignition reference pulses. If there are no ignition reference pulses, the control module shuts the fuel pump OFF within 2 seconds after the ignition was switched to the ON position or if the engine stops.
The fuel tank stores the fuel supply. The electric fuel pump supplies fuel through an in-line fuel filter to the fuel injection system. The pump provides fuel at a higher rate of flow than is needed by the fuel injection system. The fuel pressure regulator maintains the correct fuel pressure to the fuel injection system. A separate pipe returns unused fuel to the fuel tank.
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that the fuel pump is operating.
This step tests for an internal fuel leak. If the fuel pressure drops during this test, then an internal loss of pressure is indicated.
This step tests the fuel pressure regulator. The fuel pressure regulator is controlled by engine vacuum. With engine vacuum applied, the pressure should drop the specified value.
This step inspects the fuel pressure regulator for a fuel leak from the vacuum port. If fuel leaks from the fuel pressure regulator while the fuel pump is commanded ON, replace the fuel pressure regulator.
This step tests for a loss of fuel pressure between the fuel feed pipe shut-off adapter and the fuel pump.
This step tests for a leaking fuel injector, or fuel pressure regulator. If the fuel pressure remains constant during this test, the fuel injectors are not leaking fuel.
This step tests for a restricted fuel return pipe. If the fuel pressure is within the specified values, a restriction in the fuel return pipe is indicated.
This step determines if the fuel pressure regulator, or the fuel pump, is the cause of the low fuel pressure. If the pressure rises above the specified value, the fuel pump is OK.
This step verifies that a circuit condition is not the cause of a fuel pressure concern. Inspect all fuel pump electrical circuits thoroughly.
Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Fuel System Description | ||||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||||
Important: Inspect the fuel system for damage, or external leaks, before proceeding with this diagnostic.
Does the fuel pump operate? | -- | Go to Step 3 | ||||||||||
3 |
Important: Verify that there is adequate fuel in the fuel tank before proceeding with this diagnostic.
Important:
Is the fuel pressure within the specified value? | 284-325 kPa (41-47 psi) | Go to Step 4 | Go to Step 12 | ||||||||
Important: The fuel pressure may vary slightly when the fuel pump stops running. After the fuel pump stops running, the fuel pressure should stabilize and remain constant. Monitor the fuel pressure gage for 1 minute. Does the fuel pressure drop more than the specified value? | 34 kPa (5 psi) | Go to Step 9 | Go to Step 5 | |||||||||
5 |
Does the fuel pressure drop more than the second specified value? | 69 kPa (10 psi) 14 kPa (2 psi) | Go to Step 25 | Go to Step 6 | ||||||||
Does the fuel pressure drop the specified value when the engine is started? | 21-69 kPa (3-10 psi) | Go to Step 7 | Go to Step 8 | |||||||||
7 |
Do any of the scan tool parameters indicate a lean condition? | -- | Go to Step 17 | |||||||||
8 |
Does the fuel pressure drop the specified value when the vacuum is applied? | 21-69 kPa (3-10 psi) | Go to Step 22 | Go to Step 24 | ||||||||
Is the fuel pressure regulator leaking fuel? | -- | Go to Step 24 | Go to Step 10 | |||||||||
Does the fuel pressure remain constant? | -- | Go to Step 19 | Go to Step 11 | |||||||||
Does the fuel pressure remain constant? | -- | Go to Step 24 | Go to Step 20 | |||||||||
12 | Is the fuel pressure more than the specified value? | 427 kPa (62 psi) | Go to Step 14 | Go to Step 13 | ||||||||
13 | Is the fuel pressure more than the specified value? | 0 kPa (0 psi) | Go to Step 16 | Go to Step 17 | ||||||||
Is the fuel pressure within the specified value? | 284-325 kPa (41-47 psi) | Go to Step 23 | Go to Step 15 | |||||||||
15 | Inspect the fuel return pipe and the fuel rail outlet passage for a restriction. Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 24 | ||||||||
Notice: DO NOT allow the fuel pressure to exceed 517 kPa (75 psi). Excessive pressure may damage the fuel system. Does the fuel pressure rise above the specified value? | 325 kPa (47 psi) | Go to Step 24 | Go to Step 17 | |||||||||
17 | Inspect the following for a restriction:
Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 18 | ||||||||
Inspect the harness connectors and ground circuits of the fuel pump for poor connections. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 19 | |||||||||
19 |
Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 25 | ||||||||
20 |
Did you find and correct the condition? | -- | Go to Step 26 | Go to Step 21 | ||||||||
21 |
Important: Ensure that the fuel injectors are fully seated in the fuel rail before proceeding with this step. Did you complete the replacement? | 103 kPa (15 psi) | Go to Step 26 | -- | ||||||||
22 | Repair the vacuum source to the fuel pressure regulator. Did you complete the repair? | -- | Go to Step 26 | -- | ||||||||
23 | Locate and repair the restricted fuel return line. Did you complete the repair? | -- | Go to Step 26 | -- | ||||||||
24 |
Important: Inspect for a missing or damaged fuel pressure regulator O-ring seal before replacing the fuel pressure regulator. Replace the fuel pressure regulator. Refer to Fuel Pressure Regulator Replacement . Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
25 | Replace the fuel pump. Refer to Fuel Sender Assembly Replacement . Did you complete the replacement? | -- | Go to Step 26 | -- | ||||||||
26 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |