The powertrain control module (PCM) monitors the exhaust gas recirculation (EGR) valve pintle position input to ensure that the valve responds properly to commands from the PCM. The linear EGR valve is controlled by using an ignition positive driver and ground circuit within the PCM. The driver has the ability to detect an electrical malfunction in the EGR solenoid high control circuit or EGR low control circuit. If an electrical malfunction occurs, the driver signals the PCM to set DTC P0403.
• | The engine is cranking or running. |
• | The system voltage between 8-18 volts. |
• | The PCM detects an electrical malfunction in the EGR solenoid high control circuit or the EGR low control circuit. |
• | The condition is present for more than 10 seconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
Notice: Use the connector test adapter kit J 35616-A for any test that
requires probing the following items:
• The PCM harness connectors • The electrical center fuse/relay cavities • The component terminals • The component harness connector
If the problem is intermittent, refer to Intermittent Conditions .
The numbers below refer to the step numbers on the diagnostic table.
When using the scan tool to increment the EGR valve, increment the valve to 10 percent then to 0 percent . Repeat this process to see if the test lamp turns ON then OFF. If the test lamp stays ON after commanded to 0 percent the EGR solenoid high control circuit is shorted to voltage.
Tests for an open in the ground circuit to the solenoid.
Tests if voltage is constantly being applied to the solenoid.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Controls Schematics | |||
1 | Did you perform the Diagnostic System Check-Engine Controls? | Go to Step 2 | |
2 |
Does the EGR Position Sensor remain close to the Desired EGR Position at all Commanded positions? | Go to Step 3 | Go to Step 4 |
3 |
Does the DTC fail this ignition? | Go to Step 4 | Go to Intermittent Conditions |
Does the test lamp turn ON and OFF with each command? | Go to Step 5 | Go to Step 6 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 10 | Go to Step 9 | |
Does the test lamp remain illuminated with each command? | Go to Step 8 | Go to Step 7 | |
7 | Test the EGR solenoid high control circuit for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 11 |
8 | Test the EGR solenoid high control circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 11 |
9 | Test the EGR solenoid low control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the EGR. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 12 |
11 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 13 |
12 | Replace the EGR. Refer to Exhaust Gas Recirculation Valve Replacement . Did you complete the replacement? | Go to Step 14 | -- |
13 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | Go to Step 14 | -- |
14 |
Does the DTC run and pass? | Go to Step 15 | Go to Step 2 |
15 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | System OK |