8 Digit GM Part Number: The scan tool displays
the part number of the module.
Battery Voltage: The scan tool displays 0-16 volts.
The level of battery voltage at the module.
Belt Tower Down - Input: The scan tool displays
Inactive/Active. When the belt tower down switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Belt Tower Down - Output: The scan tool displays
Inactive/Active. When the belt tower down switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the belt tower motor in the down
direction
Belt Tower Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the belt tower position. High scan tool values
(Volts or A/D) indicate that the belt tower is in the up position and low
values indicate that the belt tower is in the down position.
Belt Tower Up - Input: The scan tool displays
Inactive/Active. When the belt tower up switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Belt Tower Up - Output: The scan tool displays
Inactive/Active. When the belt tower up switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the belt tower motor in the up direction.
Calibration ID: The scan tool displays a 4 digit
number. This number designates the calibration or program level used in the
PROM.
Current: The scan tool displays 0-127.5-amps.
The current measured during seat operation.
Front Vertical Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the seat front vertical position. High scan tool
values (volts or A/D) indicate that the seat front is in the up position
and low values indicate that the seat front is in the down position.
Hardware Level: The scan tool displays a 4 digit
number representing the level of hardware incorporated into the module.
Heated Seat LED: The scan tool displays Idle/High/Medium/Low
or Back-High/Back-Medium/Back-Low. These parameters indicate the mode of operation
that has been selected, while the output from the driver door module is illuminating
the selected LED.
Heated Seat Mode - Input: The scan tool displays
Off/On. When the heated seat Back Only switch is activated, the scan tool
will momentarily display the switch input to the door module as On.
Heated Seat Mode - Output: The scan tool displays
Off/On. When the heated seat Back Only switch is activated, the scan tool
will momentarily display On while the output from the door module signals
the heated seat module to deactivate the heat from the seat cushion.
Heated Seat Temperature - Input: The scan tool
displays Off/On. When the heated seat temperature switch is first activated,
the scan tool will momentarily display the switch input to the door module
as On.
Heated Seat Temperature - Output: The scan tool
displays Off/On. When the heated seat temperature switch is first activated,
the scan tool will momentarily display On, while the output from the door
module signals the heated seat module to turn on to the High heat mode. With
each additional activation of the switch, the heated seat module will increment
through the remaining temperature modes (Med/Low/Off).
Horizontal Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the seat horizontal position. High scan tool values
(volts or A/D) indicate that the seat is in the forward position and low values
indicate that the seat is in the rearward position.
Julian Date of Build: The scan tool displays a 3 digit
number. This number is the day of the year that the module was built.
Lumbar Horizontal Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the lumbar horizontal position. High scan tool
values (volts or A/D) indicate that the Lumbar is in the forward position
and low values indicate that the lumbar is in the rearward position.
Lumbar Vertical Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the lumbar vertical position. High scan tool values
(volts or A/D) indicate that the lumbar is in the up position and low values
indicate that the lumbar is in the down position.
Memory Recall Switches: The scan tool displays Idle/Memory 1/memory 2/Exit/Set.
When a memory function switch is activated, the scan tool will momentarily
display the switch input function to the driver door switch assembly (DDSA)
as selected.
Personalization Option: This is the state of the personalization
option as it is stored in the Dash Integration Module (DIM). When the Personalization
Option is selected, the scan tool displays the directions to activate or deactivate
the personalization option. The asterisk beside the option indicates that
the personalization option is activated. The personalization option
is normally set to the activated state during assembly of the vehicle.
PROM ID: The scan tool displays a 4 digit number.
This is the identification number of the PROM that is incorporated into the
module.
Rear Vertical Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the seat rear vertical position. High scan tool
values (volts or A/D) indicate that the seat rear vertical is in the up position
and low values indicate that the seat rear vertical is in the down position.
Recline Sensor: The scan tool displays 0-5.0 volts
or 0-255 A/D. The sensor potentiometer provides an analog voltage
which varies directly with the seat recline position. High scan tool values
(volts or A/D) indicate that the seat recline is in the froward position and
low values indicate that the seat recline is in the rearward position.
Seat Forward - Input: The scan tool displays Inactive/Active.
When the seat forward switch is activated, the scan tool will momentarily
display the switch input to the memory seat module as Active.
Seat Forward - Output: The scan tool displays
Inactive/Active. When the seat forward switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the seat horizontal motor in the
forward direction.
Seat Front Down - Input: The scan tool displays
Inactive/Active. When the seat front down switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Seat Front Down - Output: The scan tool displays
Inactive/Active. When the seat front down switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the seat front vertical motor in
the down direction.
Seat Front Up - Input: The scan tool displays
Inactive/Active. When the seat front up switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Seat Front Up - Output: The scan tool displays
Inactive/Active. When the seat front up switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the seat front vertical motor in
the up direction.
Seat Lumbar Down - Input: The scan tool displays
Inactive/Active. When the seat lumbar down switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Seat Lumbar Down - Output: The scan tool displays
Inactive/Active. When the seat lumbar down switch is activated or when a
memory recall occurs, the scan tool will momentarily display Active while
the output from the memory seat module is commanding the lumbar vertical
motor in the down direction.
Seat Lumbar Forward - Input: The scan tool displays
Inactive/Active. When the seat lumbar forward switch is activated, the scan
tool will momentarily display switch input to the memory seat module as
Active.
Seat Lumbar Forward - Output: The scan tool displays
Inactive/Active. When the seat lumbar forward switch is activated or when
a memory recall occurs, the scan tool will momentarily display Active
while the output from the memory seat module is commanding the lumbar
horizontal motor in the forward direction.
Seat Lumbar Rearward - Input: The scan tool displays
Inactive/Active. When the seat lumbar rearward switch is activated, the
scan tool will momentarily display the switch input to the memory seat module
as Active.
Seat Lumbar Rearward - Output: The scan tool displays
Inactive/Active. When the seat lumbar rearward switch is activated or when
a memory recall occurs, the scan tool will momentarily display Active
while the output from the memory seat module is commanding the lumbar
horizontal motor in the rearward direction.
Seat Lumbar Up - Input: The scan tool displays
Inactive/Active. When the seat lumbar up switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as Active.
Seat Lumbar Up - Output: The scan tool displays
Inactive/Active. When the seat lumbar up switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory module is commanding the lumbar vertical motor the up
direction.
Seat Rear Down - Input: The scan tool displays
Inactive/Active. When the seat rear down switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as
Active.
Seat Rear Down - Output: The scan tool displays
Inactive/Active. When the seat rear down switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the output
from the memory seat module is commanding the seat rear vertical motor
in the down direction.
Seat Rear Up - Input: The scan tool displays Inactive/Active.
When the seat rear up switch is activated, the scan tool will momentarily
display the switch input to the memory seat module as Active.
Seat Rear Up - Output: The scan tool displays
Inactive/Active. When the seat rear up switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the
output from the memory seat module is commanding the seat rear vertical
motor in the up direction.
Seat Rearward - Input: The scan tool displays
Inactive/Active. When the seat rearward switch is activated, the scan tool
will momentarily display the switch input to the memory seat module as
Active.
Seat Rearward - Output: The scan tool displays
Inactive/Active. When the seat rearward switch is activated or when a memory
recall occurs, the scan tool will momentarily display Active while the
output from the memory seat module is commanding the seat horizontal motor
in the rearward direction.
Seat Recline Forward - Input: The scan tool displays
Inactive/Active. When the seat recline forward switch is activated, the
scan tool will momentarily display the switch input to the memory seat
module as Active.
Seat Recline Forward - Output: The scan tool displays
Inactive/Active. When the seat recline forward switch is activated or a
memory recall occurs, the scan tool will momentarily display Active while
the output from the memory seat module is commanding the seat recline
motor in the forward direction.
Seat Recline Rearward - Input: The scan tool displays
Inactive/Active. When the seat recline rearward switch is activated, the
scan tool will momentarily display the switch input to the memory seat
module as Active.
Seat Recline Rearward - Output: The scan tool
displays Inactive/Active. When the seat recline rearward switch is activated
or when a memory recall occurs, the scan tool will momentarily display
Active while the output from the memory seat module is commanding the
seat recline motor in the rearward direction.
Software Level: The scan tool displays the 4 digit
number of the software incorporated into the module.
Year Module Built: The scan tool displays a 4 digit
number. This number represents the year the module was built.