Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Did the vanity mirror lamp operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Do the courtesy lamps operate properly? | Go to Step 4 | |
4 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 8 | Go to Step 6 |
6 | Test for an open or high resistance in the courtesy lamp supply voltage circuit of the vanity mirror lamp. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 9 |
7 | Inspect for poor connections at the inoperative vanity mirror lamp bulb. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 10 |
8 | Inspect for poor connections at the harness connector of the inoperative vanity mirror lamp. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 11 |
9 | Repair an open or high resistance in the ground circuit of the inoperative vanity mirror lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
10 | Replace the inoperative vanity mirror lamp bulb. Did you complete the replacement? | Go to Step 12 | -- |
11 | Replace the inoperative vanity mirror lamp. Refer to Vanity Mirror Lamp Replacement . Did you complete the replacement? | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |