Removal Procedure
Caution: Refer to SIR Caution in the Preface section.
- Remove the garnish moldings from the left and right windshield pillar. Refer to
Windshield Pillar Garnish Molding Replacement
in Interior Trim.
- Remove the I/P air outlet vents. Refer to
Instrument Panel Air Deflector Replacement
in HVAC.
- Remove the defroster grille. Refer to
Defroster Grille Replacement
.
- Remove the 4 fasteners (2) that secure the inside of the vent outlet holes to the upper pad (3).
- Remove the 3 fasteners (1) that secure the inside of the defroster grille outlet holes to the upper pad (3).
- Lift the upper I/P pad (1) upward from rear edge of the I/P cluster in order to disengage the retainers from the I/P cluster trim plate.
- Disconnect the electrical connectors if necessary.
- Lift the pad on an angle and slide rearward in order to disengage the retainers at the front of the I/P.
- Remove the I/P upper trim pad (1) from the vehicle.
Installation Procedure
- Align the I/P upper trim pad to the I/P and connect the electrical connections.
- Slide the I/P upper trim pad (1) forward in order to engage the front of the I/P trim pad to the I/P carrier.
- Align the rear edge of I/P upper trim pad (1) with the I/P cluster bezel, and snap the retainers into the upper pad.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the 4 fasteners (2) into the I/P air outlet vent openings.
Tighten
Tighten the fasteners to 2 N·m (18 lb in).
- Install the 3 fasteners (1) into the defroster grille opening on the I/P upper pad (3).
Tighten
Tighten the fasteners to 2 N·m (18 lb in).
- Install the I/P air outlets. Refer to
Instrument Panel Air Deflector Replacement
in HVAC.
- Install the defroster grille. Refer to
Defroster Grille Replacement
.
- Install the garnish moldings to the left and right windshield. Refer to
Windshield Pillar Garnish Molding Replacement
in Interior Trim.