Heated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started, the powertrain control module (PCM) operates in an Open Loop mode, ignoring the HO2S signal voltage when calculating the air-to-fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of about 450 mV. The HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage once in Closed Loop. A high HO2S voltage output indicates a rich fuel mixture. A low HO2S voltage output indicates a lean mixture. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature, and provide an accurate voltage signal. If the PCM detects that the HO2S 2 voltage remains at or near the bias voltage amount, DTC P0140 will set, the diagnostic runs once per key cycle.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0141, P0201-P0208, P0410, P0440, P0442, P0443, P0446, P0449, P1415, P1416, P1441 are not set. |
• | The system voltage is between 9-18 volts. |
• | The HO2S bank 1 sensor 2 voltage parameter is within 100 mV of the bias voltage at start-up. |
• | The Loop Status parameter is closed. |
• | The Engine Run Time parameter is over 3 minutes. |
• | The TP sensor parameter has changed by more than 5 percent at least twice. |
The PCM detects that the HO2S 1 signal voltage remains between 400-500 mV for more than 80 seconds.
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The number below refers to the step number on the diagnostic table.
Step | Action | Values | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Engine Controls Schematics Connector End View Reference: Powertrain Control Module Connector End Views or Engine Controls Connector End Views | ||||||||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||||||||
Does the HO2S voltage fluctuate above and below the specified range during the above test? | 400-520 mV | Go to Step 3 | Go to Step 4 | |||||||||||||
3 |
Did the DTC fail this ignition? | -- | Go to Step 4 | Go to Intermittent Conditions | ||||||||||||
4 |
Is the HO2S 2 voltage within the specified range? | 400-500 mV | Go to Step 5 | Go to Step 6 | ||||||||||||
5 |
Is the HO2S 2 voltage less than the specified value? | 25 mV | Go to Step 8 | Go to Step 7 | ||||||||||||
6 | Test the HO2S 2 high signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 10 | ||||||||||||
7 | Test the HO2S 2 low signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 10 | ||||||||||||
8 | Inspect for the following that may affect the HO2S operation: Notice: Refer to Silicon Contamination of Heated Oxygen Sensors Notice in the Preface section.
Notice: Refer to Heated Oxygen and Oxygen Sensor Notice in the Preface section.
Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 9 | ||||||||||||
9 | Test for an intermittent and for a poor connection at the harness connector of the HO2S 2. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 11 | ||||||||||||
10 | Test for an intermittent and for a poor connection at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 13 | Go to Step 12 | ||||||||||||
11 | Replace the HO2S 2. Refer to Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 . Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||||||||
12 | Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 13 | -- | ||||||||||||
13 |
Did the DTC fail this ignition? | -- | Go to Step 2 | Go to Step 14 | ||||||||||||
14 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | -- | System OK |