Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor operates with the HVAC controls in the OFF position. | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the blower motor turn OFF? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | With the scan tool observe the Commanded Blower parameter in the Instrument Panel Module data list. Does the scan tool indicate that the Commanded Blower parameter is near the specified value? | 0% | Go to Step 4 | Go to Step 8 |
4 | Disconnect the HVAC control module (IPM). Does the blower motor operate in any of the speed positions? | -- | Go to Step 5 | Go to Step 8 |
5 | Inspect the blower motor housing for a short to ground. Refer to Testing for Short to Ground in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 6 |
6 | Visually inspect the blower motor harness for a short to ground. Refer to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Wiring Repairs and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 9 |
8 | Inspect for poor connections at the harness connector of the IPM. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 |
9 | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
10 |
Important: Perform the recalibration procedure for the IPM. Replace the IPM. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |