Fuel door release actuation is controlled by the following
components.
• | Fuel Door Release Relay |
• | Instrument Panel Module (IPM) |
• | Rear Integration Module (RIM) |
• | Fuel Door Release Switch |
• | Fuel Door Release Actuator |
Battery voltage for the coil side of the fuel door release relay is
supplied through the Valet switch (with the valet switch in the OFF position)
by the ALDL fuse located in the Underhood Fuse (Bussed) Block. Battery
voltage for the switch side of the fuel door relay is supplied by the Body
fuse located in the Rear Fuse (Bussed) Block. When the fuel door release
switch is momentarily pressed, it provides a ground circuit for the fuel
door release signal of the Instrument Panel Module (IPM). When the IPM
senses that the switch has been activated, it sends a Serial Data Class
2 message to the Rear Integration Module (RIM). The RIM then applies a
ground path on the fuel door release actuator relay control circuit energizing
the relay thus applying battery voltage to the fuel door release actuator.
The actuator is connected to ground through a ground splice pack located
at the left rear corner of the rear compartment, near the left tail lamp
connector.