Tools Required
J 38185 Hose Clamp
Pliers
Removal Procedure
- Partially drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-4.6L.
- Position the J 38185
to the clamp in order to remove the radiator outlet hose from the
thermostat housing.
- Remove the bolts securing
the thermostat housing to the water pump inlet.
- Remove the thermostat
and the gasket from the water pump housing.
Installation Procedure
- Install the thermostat
and a new gasket into the water pump housing.
- Install the thermostat housing.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the thermostat
housing bolts.
Tighten
Tighten the thermostat housing bolts to 10 N·m (89 lb in).
- Position the J 38185
to the clamp in order to connect the radiator outlet hose to the
thermostat housing.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls-4.6L.
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.