GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The powertrain control module (PCM) provides ignition voltage to the coil side of the fuel pump relay whenever the engine is cranking or running. The control module enables the fuel pump relay as long as the engine is cranking or running, and crankshaft reference pulses are received. If no crankshaft reference pulses are received, the control module de-energizes the fuel pump.

The fuel pump relay control circuit is pulled up to 2.5 volts within the PCM using a bypass resistor that is connected internally to ignition voltage. This resistor allows the PCM to detect a high voltage condition if the fuel pump control circuit is open when the pump relay is not commanded ON. The control module monitors the voltage on the fuel pump relay control circuit. If the PCM detects a low voltage condition on the control circuit with the engine cranking or running, DTC P0628 sets.

DTC Descriptor

This diagnostic procedure supports the following DTC:

DTC P0628 Fuel Pump Relay Control Circuit Low Voltage

Conditions for Running the DTC

    • The engine speed is more than 80 RPM.
    • The engine controls ignition relay voltage is between 10-18 volts.
    • The PCM has commanded the fuel pump relay ON and OFF at least once during the ignition cycle.
    • DTC P0628 runs continuously once the above conditions have been met.

Conditions for Setting the DTC

    • The PCM detects the voltage on the fuel pump relay control circuit is less than 2.21 volts.
    • The condition exists for less than 1 second.

Action Taken When the DTC Sets

    • The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
    • The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.

Conditions for Clearing the MIL/DTC

    • The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
    • A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
    • A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
    • Clear the MIL and the DTC with a scan tool.

Diagnostic Aids

    •  The circuit status parameter changes from OK to Fault if there is a condition with the circuit or a connection.
    • For an intermittent condition, refer to Intermittent Conditions .

Test Description

The number below refers to the step number on the diagnostic table.

  1. This step verifies that the control module is providing voltage to the fuel pump relay.

Step

Action

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Powertrain Control Module Connector End Views or Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check - Vehicle?

Go to Step 2

Go to Diagnostic System Check - Vehicle in Vehicle DTC Information

2

  1. Turn ON the ignition, with the engine OFF.
  2. Command the fuel pump ON and OFF with a scan tool.

Does the fuel pump relay turn ON and OFF with each command?

Go to Step 3

Go to Step 4

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 4

Go to Intermittent Conditions

4

  1. Turn OFF the ignition.
  2. Disconnect the fuel pump relay.
  3. Turn ON the ignition, with the engine OFF.
  4. Probe the control circuit of the fuel pump relay with a test lamp connected to the powertrain control module (PCM) housing.
  5. Command the fuel pump ON and OFF with a scan tool.

Does the test lamp turn ON and OFF?

Go to Step 6

Go to Step 5

5

Test the control circuit of the fuel pump relay for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

Go to Step 8

Go to Step 7

6

Replace the fuel pump relay.

Did you complete the replacement?

Go to Step 8

--

7

Replace the PCM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming.

Did you complete the replacement?

Go to Step 8

--

8

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records.

Did the DTC fail this ignition?

Go to Step 2

Go to Step 9

9

Observe the Capture Info with a scan tool.

Are there any DTCs that have not been diagnosed?

Go to Diagnostic Trouble Code (DTC) List - Vehicle in Vehicle DTC Information

System OK