GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Cadillac
🢒
2005
🢒
DeVille
🢒
HVAC
🢒
Heating, Ventilation and Air Conditioning
🢒 Service Ports Replacement
Tools Required
J 39400-A
Halogen Leak Detector
Removal Procedure
Remove the service port cap.
Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
Remove the service fitting from the evaporator hose.
Remove and discard the O-ring from the evaporator hose. Refer to
O-Ring Replacement
.
Installation Procedure
Install a new O-ring to the evaporator hose. Refer to
O-Ring Replacement
.
Install the service fitting to the evaporator hose.
Tighten
Tighten the fitting to 12 N·m (106 lb in).
Recharge the refrigerant system. Refer to
Refrigerant Recovery and Recharging
.
Leak test the fittings using the
J 39400-A
.
Install the service port cap.